{"product_id":"test-rapido-screen-psa-prostate-sangue-intero-siero-plasma-conf-40-pz","title":"40 pieces","description":"\u003ch2 data-end=\"211\" data-section-id=\"qktjnc\" data-start=\"174\"\u003eScreen Test PSA – Rapid PSA Test\u003c\/h2\u003e\u003cp data-end=\"374\" data-start=\"212\"\u003e\u003cstrong data-end=\"283\" data-start=\"212\"\u003eSemi-quantitative rapid test for Prostate Specific Antigen PSA\u003c\/strong\u003e\u003cbr data-end=\"286\" data-start=\"283\"\/\u003e\u003cstrong data-end=\"329\" data-start=\"286\"\u003eSample: whole blood, serum or plasma\u003c\/strong\u003e\u003cbr data-end=\"332\" data-start=\"329\"\/\u003e\u003cstrong data-end=\"374\" data-start=\"332\"\u003eProfessional in vitro diagnostic use\u003c\/strong\u003e\u003c\/p\u003e\u003ch2 data-end=\"399\" data-section-id=\"38zs35\" data-start=\"376\"\u003eProduct description\u003c\/h2\u003e\u003cp data-end=\"588\" data-start=\"401\"\u003e\u003cstrong data-end=\"420\" data-start=\"401\"\u003eScreen Test PSA\u003c\/strong\u003e is a rapid immunochromatographic test for the semi-quantitative detection of \u003cstrong data-end=\"538\" data-start=\"501\"\u003eProstate Specific Antigen PSA\u003c\/strong\u003e in \u003cstrong data-end=\"587\" data-start=\"554\"\u003ewhole blood, serum or plasma\u003c\/strong\u003e samples.\u003c\/p\u003e\u003cp data-end=\"821\" data-start=\"590\"\u003eThe test is intended exclusively for \u003cstrong data-end=\"669\" data-start=\"627\"\u003eprofessional in vitro diagnostic use\u003c\/strong\u003e and is indicated as an aid in identifying PSA levels, a parameter commonly used in the clinical assessment of prostate health.\u003c\/p\u003e\u003cp data-end=\"1014\" data-start=\"823\"\u003eThe device enables rapid result reading, with reference values useful for distinguishing PSA levels below 3 ng\/mL, between 3 and 10 ng\/mL, or above 10 ng\/mL.\u003c\/p\u003e\u003ch2 data-end=\"1045\" data-section-id=\"d437e9\" data-start=\"1016\"\u003eMain features\u003c\/h2\u003e\u003cul data-end=\"1419\" data-start=\"1047\"\u003e\u003cli data-end=\"1082\" data-section-id=\"80ud\" data-start=\"1047\"\u003eSemi-quantitative PSA rapid test\u003c\/li\u003e\u003cli data-end=\"1131\" data-section-id=\"1c24jbb\" data-start=\"1083\"\u003eUsable with whole blood, serum or plasma\u003c\/li\u003e\u003cli data-end=\"1171\" data-section-id=\"b2heg5\" data-start=\"1132\"\u003eResult reading in \u003cstrong data-end=\"1171\" data-start=\"1159\"\u003e5 minutes\u003c\/strong\u003e\u003c\/li\u003e\u003cli data-end=\"1222\" data-section-id=\"14y8sff\" data-start=\"1172\"\u003eDo not interpret the result after \u003cstrong data-end=\"1222\" data-start=\"1209\"\u003e10 minutes\u003c\/strong\u003e\u003c\/li\u003e\u003cli data-end=\"1251\" data-section-id=\"1pmct16\" data-start=\"1223\"\u003eCut-off value: \u003cstrong data-end=\"1251\" data-start=\"1240\"\u003e3 ng\/mL\u003c\/strong\u003e\u003c\/li\u003e\u003cli data-end=\"1289\" data-section-id=\"11cdwp0\" data-start=\"1252\"\u003eReference value: \u003cstrong data-end=\"1289\" data-start=\"1277\"\u003e10 ng\/mL\u003c\/strong\u003e\u003c\/li\u003e\u003cli data-end=\"1339\" data-section-id=\"pha8z2\" data-start=\"1290\"\u003eFor professional in vitro diagnostic use only\u003c\/li\u003e\u003cli data-end=\"1404\" data-section-id=\"12u1o7i\" data-start=\"1340\"\u003eStorage at room temperature or refrigerated: \u003cstrong data-end=\"1404\" data-start=\"1394\"\u003e2-30°C\u003c\/strong\u003e\u003c\/li\u003e\u003cli data-end=\"1419\" data-section-id=\"infyhg\" data-start=\"1405\"\u003eSingle-use test\u003c\/li\u003e\u003c\/ul\u003e\u003ch2 data-end=\"1436\" data-section-id=\"79n34s\" data-start=\"1421\"\u003eIntended use\u003c\/h2\u003e\u003cp data-end=\"1609\" data-start=\"1438\"\u003eThe PSA Rapid Test is a rapid chromatographic immunoassay for the semi-quantitative detection of Prostate Specific Antigen in whole blood, serum or plasma.\u003c\/p\u003e\u003ch2 data-end=\"1632\" data-section-id=\"1svfdaf\" data-start=\"1611\"\u003eTest principle\u003c\/h2\u003e\u003cp data-end=\"1772\" data-start=\"1634\"\u003eThe test uses a combination of anti-PSA antibodies and colloidal gold conjugate to selectively detect total PSA in the sample.\u003c\/p\u003e\u003cp data-end=\"1885\" data-start=\"1774\"\u003eThe appearance and intensity of the colored lines allow a semi-quantitative assessment of the PSA level.\u003c\/p\u003e\u003ch2 data-end=\"1919\" data-section-id=\"w9sqet\" data-start=\"1887\"\u003eResult interpretation\u003c\/h2\u003e\u003cp data-end=\"2107\" data-start=\"1921\"\u003e\u003cstrong data-end=\"1933\" data-start=\"1921\"\u003eNegative\u003c\/strong\u003e\u003cbr data-end=\"1936\" data-start=\"1933\"\/\u003eThe lines appear in the control zone \u003cstrong data-end=\"1984\" data-start=\"1979\"\u003eC\u003c\/strong\u003e and in the reference zone \u003cstrong data-end=\"2018\" data-start=\"2013\"\u003eR\u003c\/strong\u003e, but the test line \u003cstrong data-end=\"2054\" data-start=\"2049\"\u003eT\u003c\/strong\u003e does not appear.\u003cbr data-end=\"2058\" data-start=\"2055\"\/\u003eIndicates a PSA level below \u003cstrong data-end=\"2106\" data-start=\"2095\"\u003e3 ng\/mL\u003c\/strong\u003e.\u003c\/p\u003e\u003cp data-end=\"2234\" data-start=\"2109\"\u003e\u003cstrong data-end=\"2138\" data-start=\"2109\"\u003ePositive between 3 and 10 ng\/mL\u003c\/strong\u003e\u003cbr data-end=\"2141\" data-start=\"2138\"\/\u003eThe test line \u003cstrong data-end=\"2160\" data-start=\"2155\"\u003eT\u003c\/strong\u003e appears with lower intensity than the reference line \u003cstrong data-end=\"2233\" data-start=\"2228\"\u003eR\u003c\/strong\u003e.\u003c\/p\u003e\u003cp data-end=\"2359\" data-start=\"2236\"\u003e\u003cstrong data-end=\"2275\" data-start=\"2236\"\u003ePositive around 10 ng\/mL or higher\u003c\/strong\u003e\u003cbr data-end=\"2278\" data-start=\"2275\"\/\u003eThe test line \u003cstrong data-end=\"2297\" data-start=\"2292\"\u003eT\u003c\/strong\u003e has the same or similar intensity as the reference line \u003cstrong data-end=\"2358\" data-start=\"2353\"\u003eR\u003c\/strong\u003e.\u003c\/p\u003e\u003cp data-end=\"2528\" data-start=\"2361\"\u003e\u003cstrong data-end=\"2380\" data-start=\"2361\"\u003eInvalid result\u003c\/strong\u003e\u003cbr data-end=\"2383\" data-start=\"2380\"\/\u003eIf the control line \u003cstrong data-end=\"2425\" data-start=\"2420\"\u003eC\u003c\/strong\u003e or the reference line \u003cstrong data-end=\"2457\" data-start=\"2452\"\u003eR\u003c\/strong\u003e does not appear, the test is invalid and must be repeated with a new device.\u003c\/p\u003e\u003ch2 data-end=\"2554\" data-section-id=\"1qrrnh5\" data-start=\"2530\"\u003eUsable samples\u003c\/h2\u003e\u003cp data-end=\"2588\" data-start=\"2556\"\u003eThe test can be performed with:\u003c\/p\u003e\u003cul data-end=\"2666\" data-start=\"2590\"\u003e\u003cli data-end=\"2620\" data-section-id=\"1ekhmsg\" data-start=\"2590\"\u003eWhole blood from venipuncture\u003c\/li\u003e\u003cli data-end=\"2649\" data-section-id=\"2dg66\" data-start=\"2621\"\u003eWhole blood from finger prick\u003c\/li\u003e\u003cli data-end=\"2657\" data-section-id=\"178fmmi\" data-start=\"2650\"\u003eSerum\u003c\/li\u003e\u003cli data-end=\"2666\" data-section-id=\"34nw7e\" data-start=\"2658\"\u003ePlasma\u003c\/li\u003e\u003c\/ul\u003e\u003ch2 data-end=\"2695\" data-section-id=\"sqdcpp\" data-start=\"2668\"\u003eBrief instructions for use\u003c\/h2\u003e\u003cp data-end=\"2794\" data-start=\"2697\"\u003eBring the test, sample and buffer to room temperature, between \u003cstrong data-end=\"2772\" data-start=\"2757\"\u003e15°C and 30°C\u003c\/strong\u003e, before use.\u003c\/p\u003e\u003cp data-end=\"2931\" data-start=\"2796\"\u003eFor serum or plasma:\u003cbr data-end=\"2818\" data-start=\"2815\"\/\u003eadd \u003cstrong data-end=\"2853\" data-start=\"2829\"\u003e1 drop of sample\u003c\/strong\u003e, about 40 µL, into the test well and then \u003cstrong data-end=\"2930\" data-start=\"2908\"\u003e1 drop of buffer\u003c\/strong\u003e.\u003c\/p\u003e\u003cp data-end=\"3064\" data-start=\"2933\"\u003eFor whole blood from venipuncture:\u003cbr data-end=\"2969\" data-start=\"2966\"\/\u003eadd \u003cstrong data-end=\"3008\" data-start=\"2980\"\u003e2 drops of whole blood\u003c\/strong\u003e, about 80 µL, and then \u003cstrong data-end=\"3063\" data-start=\"3041\"\u003e1 drop of buffer\u003c\/strong\u003e.\u003c\/p\u003e\u003cp data-end=\"3220\" data-start=\"3066\"\u003eFor whole blood from finger prick:\u003cbr data-end=\"3100\" data-start=\"3097\"\/\u003eapply about \u003cstrong data-end=\"3135\" data-start=\"3116\"\u003e80 µL of blood\u003c\/strong\u003e using a capillary tube or 2 drops of blood and add \u003cstrong data-end=\"3219\" data-start=\"3197\"\u003e1 drop of buffer\u003c\/strong\u003e.\u003c\/p\u003e\u003cp data-end=\"3261\" data-start=\"3222\"\u003eRead the result after \u003cstrong data-end=\"3260\" data-start=\"3248\"\u003e5 minutes\u003c\/strong\u003e.\u003c\/p\u003e\u003ch2 data-end=\"3283\" data-section-id=\"1ltsf2e\" data-start=\"3263\"\u003eSupplied materials\u003c\/h2\u003e\u003cul data-end=\"3347\" data-start=\"3285\"\u003e\u003cli data-end=\"3300\" data-section-id=\"9211qw\" data-start=\"3285\"\u003eTest devices\u003c\/li\u003e\u003cli data-end=\"3313\" data-section-id=\"2ux6oi\" data-start=\"3301\"\u003eDroppers\u003c\/li\u003e\u003cli data-end=\"3322\" data-section-id=\"1w1yvu0\" data-start=\"3314\"\u003eBuffer\u003c\/li\u003e\u003cli data-end=\"3347\" data-section-id=\"1yeh1id\" data-start=\"3323\"\u003eInstructions leaflet\u003c\/li\u003e\u003c\/ul\u003e\u003ch2 data-end=\"3386\" data-section-id=\"7hlz2q\" data-start=\"3349\"\u003eMaterials required but not supplied\u003c\/h2\u003e\u003cul data-end=\"3583\" data-start=\"3388\"\u003e\u003cli data-end=\"3423\" data-section-id=\"lid0bw\" data-start=\"3388\"\u003eSample collection containers\u003c\/li\u003e\u003cli data-end=\"3431\" data-section-id=\"177wai7\" data-start=\"3424\"\u003eTimer\u003c\/li\u003e\u003cli data-end=\"3476\" data-section-id=\"1e0acny\" data-start=\"3432\"\u003eCentrifuge, if needed for serum\/plasma\u003c\/li\u003e\u003cli data-end=\"3511\" data-section-id=\"1ebfxde\" data-start=\"3477\"\u003eLancets for finger-prick blood\u003c\/li\u003e\u003cli data-end=\"3583\" data-section-id=\"15kmow5\" data-start=\"3512\"\u003eHeparinized capillary tubes and dispensing bulb, if needed\u003c\/li\u003e\u003c\/ul\u003e\u003ch2 data-end=\"3610\" data-section-id=\"12duzsj\" data-start=\"3585\"\u003eDeclared performance\u003c\/h2\u003e\u003cp data-end=\"3711\" data-start=\"3612\"\u003eThe PSA Rapid Test was compared with a market-leading PSA ELISA test on clinical samples.\u003c\/p\u003e\u003cul data-end=\"3812\" data-start=\"3713\"\u003e\u003cli data-end=\"3746\" data-section-id=\"1hmqtfn\" data-start=\"3713\"\u003eRelative sensitivity: \u003cstrong data-end=\"3746\" data-start=\"3737\"\u003e99.0%\u003c\/strong\u003e\u003c\/li\u003e\u003cli data-end=\"3780\" data-section-id=\"jeazb8\" data-start=\"3747\"\u003eRelative specificity: \u003cstrong data-end=\"3780\" data-start=\"3771\"\u003e99.2%\u003c\/strong\u003e\u003c\/li\u003e\u003cli data-end=\"3812\" data-section-id=\"197hc7u\" data-start=\"3781\"\u003eOverall accuracy: \u003cstrong data-end=\"3812\" data-start=\"3803\"\u003e99.1%\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2 data-end=\"3830\" data-section-id=\"7zmweb\" data-start=\"3814\"\u003eStorage\u003c\/h2\u003e\u003cp data-end=\"3994\" data-start=\"3832\"\u003eStore the kit at room temperature or refrigerated, between \u003cstrong data-end=\"3906\" data-start=\"3892\"\u003e2°C and 30°C\u003c\/strong\u003e.\u003cbr data-end=\"3910\" data-start=\"3907\"\/\u003eDo not freeze.\u003cbr data-end=\"3927\" data-start=\"3924\"\/\u003eDo not use after the expiry date indicated on the package.\u003c\/p\u003e\u003ch2 data-end=\"4009\" data-section-id=\"ty3syb\" data-start=\"3996\"\u003eWarnings\u003c\/h2\u003e\u003cul data-end=\"4441\" data-start=\"4011\"\u003e\u003cli data-end=\"4060\" data-section-id=\"pha8z2\" data-start=\"4011\"\u003eFor professional in vitro diagnostic use only\u003c\/li\u003e\u003cli data-end=\"4108\" data-section-id=\"1jtkfes\" data-start=\"4061\"\u003eDo not use if the package is damaged\u003c\/li\u003e\u003cli data-end=\"4168\" data-section-id=\"1mleekm\" data-start=\"4109\"\u003eHandle all samples as potentially infectious\u003c\/li\u003e\u003cli data-end=\"4248\" data-section-id=\"89ez6o\" data-start=\"4169\"\u003eWear personal protective equipment during the test\u003c\/li\u003e\u003cli data-end=\"4345\" data-section-id=\"161pqjf\" data-start=\"4249\"\u003eThe test must not be used as the sole criterion for diagnosing prostate cancer\u003c\/li\u003e\u003cli data-end=\"4441\" data-section-id=\"1unzdbm\" data-start=\"4346\"\u003eResults must be interpreted by the physician together with other clinical and diagnostic data\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Securlab","offers":[{"title":"Default Title","offer_id":57603197403518,"sku":"TPS-402(SC-0890-40)","price":76.32,"currency_code":"EUR","in_stock":true}],"url":"https:\/\/www.securlab.it\/en\/products\/40-pieces","provider":"Securlab","version":"1.0","type":"link"}