{"product_id":"cupola-aspirante-mod-901-a-completa-di-filtro-hepa-prefiltro-ma-senza-filtro-a-carboni-certificata-tuv","title":"Aspirating dome MOD. 901\/A complete with HEPA filter, pre-filter but without TUV certified carbon filter","description":"\u003cp\u003e\u003c\/p\u003e\u003ch2 data-end=\"63\" data-section-id=\"euc897\" data-start=\"0\"\u003e\u003cstrong data-end=\"61\" data-start=\"3\"\u003eBench Aspirating Dome Mod. 901 with HEPA H14 Filter\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3 data-end=\"85\" data-section-id=\"i2f1cr\" data-start=\"64\"\u003e\u003cstrong data-end=\"83\" data-start=\"68\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-end=\"684\" data-start=\"86\"\u003eThe aspirating dome Mod. 901 is a bench hood designed to protect the operator during processes that generate dust or aerosols. Equipped with a high-efficiency HEPA H14 filter (99.995% on particles ≥0.3 microns), it ensures a high air filtration capacity, making it ideal for analysis laboratories, pathological anatomy, and technical environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e It is particularly suitable for all operations where the safety of the operator and the environment is essential, but protection of the product from external contamination is not required.\u003c\/p\u003e\u003ch3 data-end=\"721\" data-section-id=\"14y6kgi\" data-start=\"685\"\u003e\u003cstrong data-end=\"719\" data-start=\"689\"\u003eMain Features\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-end=\"1202\" data-start=\"722\"\u003e\u003cli data-end=\"770\" data-section-id=\"7jnuk1\" data-start=\"722\"\u003e\u003cp data-end=\"770\" data-start=\"724\"\u003eBench aspirating hood with HEPA H14 filter\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"815\" data-section-id=\"enjjki\" data-start=\"771\"\u003e\u003cp data-end=\"815\" data-start=\"773\"\u003eFiltration efficiency 99.995% (EN 1822)\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"862\" data-section-id=\"c3ea6u\" data-start=\"816\"\u003e\u003cp data-end=\"862\" data-start=\"818\"\u003eIdeal for handling powders and aerosols\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"914\" data-section-id=\"3n1l9j\" data-start=\"863\"\u003e\u003cp data-end=\"914\" data-start=\"865\"\u003eSteel structure with acid-resistant coating\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"961\" data-section-id=\"jqsb4r\" data-start=\"915\"\u003e\u003cp data-end=\"961\" data-start=\"917\"\u003eDome and front made of transparent Plexiglas\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1018\" data-section-id=\"6j4ttp\" data-start=\"962\"\u003e\u003cp data-end=\"1018\" data-start=\"964\"\u003eRemovable work surface in AISI 316L stainless steel\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1076\" data-section-id=\"xgq7t\" data-start=\"1019\"\u003e\u003cp data-end=\"1076\" data-start=\"1021\"\u003eQuiet fan with adjustable speed\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1126\" data-section-id=\"5kitl0\" data-start=\"1077\"\u003e\u003cp data-end=\"1126\" data-start=\"1079\"\u003eDigital control panel with microprocessor\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1166\" data-section-id=\"e5o7av\" data-start=\"1127\"\u003e\u003cp data-end=\"1166\" data-start=\"1129\"\u003eFilter hour counter and service outlet\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1202\" data-section-id=\"2eb7yd\" data-start=\"1167\"\u003e\u003cp data-end=\"1202\" data-start=\"1169\"\u003eInstallable on any bench\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3 data-end=\"1221\" data-section-id=\"4nsmeb\" data-start=\"1203\"\u003e\u003cstrong data-end=\"1219\" data-start=\"1207\"\u003eAdvantages\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-end=\"1492\" data-start=\"1222\"\u003e\u003cli data-end=\"1276\" data-section-id=\"1i4vkeu\" data-start=\"1222\"\u003e\u003cp data-end=\"1276\" data-start=\"1224\"\u003eEffective protection for the operator and the environment\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1331\" data-section-id=\"izmd7p\" data-start=\"1277\"\u003e\u003cp data-end=\"1331\" data-start=\"1279\"\u003eReduction of the risk of contamination from dust\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1371\" data-section-id=\"yfhykh\" data-start=\"1332\"\u003e\u003cp data-end=\"1371\" data-start=\"1334\"\u003eEase of use and maintenance\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1426\" data-section-id=\"piqic5\" data-start=\"1372\"\u003e\u003cp data-end=\"1426\" data-start=\"1374\"\u003eRobust structure resistant to chemicals\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1457\" data-section-id=\"sqchq1\" data-start=\"1427\"\u003e\u003cp data-end=\"1457\" data-start=\"1429\"\u003eLow noise level (≤ 60 dB)\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1492\" data-section-id=\"e16cdx\" data-start=\"1458\"\u003e\u003cp data-end=\"1492\" data-start=\"1460\"\u003eHigh reliability over time\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3 data-end=\"1515\" data-section-id=\"1494xmj\" data-start=\"1493\"\u003e\u003cstrong data-end=\"1513\" data-start=\"1497\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-end=\"1697\" data-start=\"1516\"\u003e\u003cli data-end=\"1541\" data-section-id=\"1odjgiv\" data-start=\"1516\"\u003e\u003cp data-end=\"1541\" data-start=\"1518\"\u003eAnalysis laboratories\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1565\" data-section-id=\"1fqlm65\" data-start=\"1542\"\u003e\u003cp data-end=\"1565\" data-start=\"1544\"\u003ePathological anatomy\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1579\" data-section-id=\"q40xx1\" data-start=\"1566\"\u003e\u003cp data-end=\"1579\" data-start=\"1568\"\u003eCytology\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1615\" data-section-id=\"zvqjjb\" data-start=\"1580\"\u003e\u003cp data-end=\"1615\" data-start=\"1582\"\u003ePreparation of biological samples\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1652\" data-section-id=\"gzgka1\" data-start=\"1616\"\u003e\u003cp data-end=\"1652\" data-start=\"1618\"\u003eWeighing and handling powders\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1697\" data-section-id=\"6jq80p\" data-start=\"1653\"\u003e\u003cp data-end=\"1697\" data-start=\"1655\"\u003eProtection for centrifuges and equipment\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3 data-end=\"1731\" data-section-id=\"ljymuy\" data-start=\"1698\"\u003e\u003cstrong data-end=\"1729\" data-start=\"1702\"\u003eMain Technical Data\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-end=\"2021\" data-start=\"1732\"\u003e\u003cli data-end=\"1778\" data-section-id=\"359rih\" data-start=\"1732\"\u003e\u003cp data-end=\"1778\" data-start=\"1734\"\u003eWorking area dimensions: 600 x 285 x 360 mm\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1821\" data-section-id=\"1r6g96s\" data-start=\"1779\"\u003e\u003cp data-end=\"1821\" data-start=\"1781\"\u003eExternal dimensions: 675 x 560 x 530 mm\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1856\" data-section-id=\"1xogcpq\" data-start=\"1822\"\u003e\u003cp data-end=\"1856\" data-start=\"1824\"\u003eFiltered air volume: 135 m³\/h\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1884\" data-section-id=\"18lj5fz\" data-start=\"1857\"\u003e\u003cp data-end=\"1884\" data-start=\"1859\"\u003eAir speed: 0.50 m\/s\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1908\" data-section-id=\"rjg9j4\" data-start=\"1885\"\u003e\u003cp data-end=\"1908\" data-start=\"1887\"\u003eNoise level: ≤ 60 dB\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1924\" data-section-id=\"sbgy9i\" data-start=\"1909\"\u003e\u003cp data-end=\"1924\" data-start=\"1911\"\u003eWeight: 45 kg\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1960\" data-section-id=\"1xvg9ku\" data-start=\"1925\"\u003e\u003cp data-end=\"1960\" data-start=\"1927\"\u003eFront opening: 180 – 380 mm\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1985\" data-section-id=\"3vlcna\" data-start=\"1961\"\u003e\u003cp data-end=\"1985\" data-start=\"1963\"\u003ePre-filter: ePM10 50%\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2021\" data-section-id=\"vsmhab\" data-start=\"1986\"\u003e\u003cp data-end=\"2021\" data-start=\"1988\"\u003eHEPA filter: class H14 (ISO 5)\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3 data-end=\"2046\" data-section-id=\"1sqwog3\" data-start=\"2022\"\u003e\u003cstrong data-end=\"2044\" data-start=\"2026\"\u003eElectrical Data\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-end=\"2132\" data-start=\"2047\"\u003e\u003cli data-end=\"2078\" data-section-id=\"1lpq9o1\" data-start=\"2047\"\u003e\u003cp data-end=\"2078\" data-start=\"2049\"\u003ePower supply: 230V – 50 Hz\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2109\" data-section-id=\"pbo2v9\" data-start=\"2079\"\u003e\u003cp data-end=\"2109\" data-start=\"2081\"\u003ePower consumption: 60 W + 440 W\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2132\" data-section-id=\"1043for\" data-start=\"2110\"\u003e\u003cp data-end=\"2132\" data-start=\"2112\"\u003eFuses: 2 x 3 AF\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3 data-end=\"2170\" data-section-id=\"a62jmd\" data-start=\"2133\"\u003e\u003cstrong data-end=\"2168\" data-start=\"2137\"\u003eCompliance and Certifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-end=\"2307\" data-start=\"2171\"\u003e\u003cli data-end=\"2220\" data-section-id=\"19xnker\" data-start=\"2171\"\u003e\u003cp data-end=\"2220\" data-start=\"2173\"\u003eDirectives: 2014\/35\/EU, 2014\/30\/EU, 2006\/42\/EC\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2256\" data-section-id=\"143ekp7\" data-start=\"2221\"\u003e\u003cp data-end=\"2256\" data-start=\"2223\"\u003eStandards: UNI EN 14175, EN 61010-1\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2278\" data-section-id=\"u13s7x\" data-start=\"2257\"\u003e\u003cp data-end=\"2278\" data-start=\"2259\"\u003eCE Certification\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2307\" data-section-id=\"1grakz9\" data-start=\"2279\"\u003e\u003cp data-end=\"2307\" data-start=\"2281\"\u003eISO 9001 Quality System\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3 data-end=\"2339\" data-section-id=\"78yavy\" data-start=\"2308\"\u003e\u003cstrong data-end=\"2337\" data-start=\"2312\"\u003eAvailable Accessories\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-end=\"2487\" data-start=\"2340\"\u003e\u003cli data-end=\"2391\" data-section-id=\"1lgcxuj\" data-start=\"2340\"\u003e\u003cp data-end=\"2391\" data-start=\"2342\"\u003eAir duct for external discharge Ø 100 mm\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2422\" data-section-id=\"xax9z3\" data-start=\"2392\"\u003e\u003cp data-end=\"2422\" data-start=\"2394\"\u003eSupport with or without wheels\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2487\" data-section-id=\"cn84lh\" data-start=\"2423\"\u003e\u003cp data-end=\"2487\" data-start=\"2425\"\u003eActivated carbon filters (also impregnated for specific gases)\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3 data-end=\"2516\" data-section-id=\"if0jr9\" data-start=\"2488\"\u003e\u003cstrong data-end=\"2514\" data-start=\"2492\"\u003eIntended Use\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-end=\"2645\" data-start=\"2517\"\u003eDevice intended to protect the operator during laboratory activities with the emission of airborne particles.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"ASAL","offers":[{"title":"Default Title","offer_id":57603408265598,"sku":"AS29940033","price":1953.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0959\/4873\/4846\/files\/AS29940033_--_000_53504.jpg?v=1782256511","url":"https:\/\/www.securlab.it\/en\/products\/aspirating-dome-mod-901-a-complete-with-hepa-filter-pre-filter-but-without-tuv-certified-carbon-filter","provider":"Securlab","version":"1.0","type":"link"}