{"product_id":"pompa-volumetrica-peristaltica-b-braun-spaceplus-infusomat","title":"B. Braun SpacePlus Infusomat peristaltic volumetric pump","description":"\u003ch2\u003eB. Braun SpacePlus Infusomat® peristaltic volumetric pump\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSpacePlus Infusomat®\u003c\/strong\u003e by B. Braun is a \u003cstrong\u003esingle-channel peristaltic infusion pump\u003c\/strong\u003e, portable, for the administration via \u003cstrong\u003eparenteral (venous or arterial)\u003c\/strong\u003e and \u003cstrong\u003eenteral\u003c\/strong\u003e of \u003cstrong\u003elarge and small volumes\u003c\/strong\u003e of drugs, blood transfusions, infusion solutions and nutritional solutions.\u003c\/p\u003e\u003ch3\u003eOperating advantages\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eIntuitive and standardized user interface for B. Braun Space pumps\u003c\/li\u003e\u003cli\u003eAutomatic calculation of infusion rate based on volume and duration\u003c\/li\u003e\u003cli\u003eAutomatic calculation of administration rate based on drug concentration and desired dosage\u003c\/li\u003e\u003cli\u003eBattery autonomy: about 11 h with Wi-Fi active, 13 h with Wi-Fi disabled\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eDrug library\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eUp to 10,000 drugs can be stored with therapy data\u003c\/li\u003e\u003cli\u003eOrganization into 30 categories\u003c\/li\u003e\u003cli\u003eDefinition of specific infusion limits and standard values for each drug\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSafety\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFree-flow prevention device integrated into the pump and infusion set during door opening or removal of the infusion set\u003c\/li\u003e\u003cli\u003eAutomatic bolus reduction following an occlusion alarm (with additional pressure sensor for upstream occlusions)\u003c\/li\u003e\u003cli\u003eData lock (parameters and\/or disposable devices) on 3 security levels\u003c\/li\u003e\u003cli\u003eAlarms with error messages on the display\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThe pump can be used alone or with the \u003cstrong\u003eB. Braun Space system (optional)\u003c\/strong\u003e, for housing the pumps in an infusion station with power supply and data transmission (if provided) of therapy information.\u003c\/p\u003e\u003ch3\u003eRegulatory compliance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eIEC\/EN 60601-1\u003c\/li\u003e\u003cli\u003eIEC\/EN 60601-2-24\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\u003cli\u003ePower cable for B. Braun pumps\u003c\/li\u003e\u003cli\u003eInfusomat Space Line infusion set with injection port\u003c\/li\u003e\u003cli\u003eInfusomat Space Line infusion set for blood products\u003c\/li\u003e\u003cli\u003eInfusomat Space Line Standard infusion set\u003c\/li\u003e\u003cli\u003eSpacePlus Pump Clamp – clamp for SpacePlus pumps\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eStandard equipment\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eSpacePlus Infusomat® pump\u003c\/li\u003e\u003cli\u003eIntegrated rechargeable lithium-ion battery\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower supply not included\u003c\/strong\u003e (to be purchased separately).\u003c\/p\u003e\u003ch3\u003eTechnical information\u003c\/h3\u003e\u003ch4\u003eSpeed range (continuous infusion)\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e0.1 – 1,200 ml\/h\u003c\/li\u003e\u003cli\u003ePossibility of changing speed without interrupting the infusion\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpeed increments\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eMicro mode: 0.01 ml\/h for speeds \u003c 99.99 ml\/h\u003c\/li\u003e\u003cli\u003eMacro mode: 0.1 ml\/h for speeds 100 – 999.9 ml\/h\u003c\/li\u003e\u003cli\u003eMacro mode: 1 ml\/h for speeds \u003e 1000 ml\/h\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eBolus function\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eBolus speed: 1 – 1,200 ml\/h\u003c\/li\u003e\u003cli\u003eProgrammable bolus (volume and duration) via “Bolus on demand”\u003c\/li\u003e\u003cli\u003eReuse of the programmed bolus with the possibility of modifying parameters\u003c\/li\u003e\u003cli\u003eManual bolus: delivery while the button is kept pressed\u003c\/li\u003e\u003cli\u003eCalculation of the total infused bolus volume\u003c\/li\u003e\u003cli\u003eBolus without stopping the infusion with automatic restart at the end of the bolus\u003c\/li\u003e\u003cli\u003ePossibility to recall the last infused bolus\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eVolume and duration\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eVolume preset: 0.01 – 9,999 ml\u003c\/li\u003e\u003cli\u003eQuick entry of volumes with frequent values shown on the display (customizable)\u003c\/li\u003e\u003cli\u003eVolume increments: 0.01 ml (0.1–99.99 ml) \/ 0.1 ml (100–999.9 ml) \/ 1 ml (1000–9999 ml)\u003c\/li\u003e\u003cli\u003eDuration preset: 00:00:00 – 99:59:59 (h:min:s)\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eAccuracy\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eInfusion accuracy: ±3% with dedicated Infusomat® Space Line infusion sets\u003c\/li\u003e\u003cli\u003eAccuracy maintained up to 96 h with dedicated Infusomat® Space Line infusion set\u003c\/li\u003e\u003cli\u003eMechanical accuracy (pump only): \u003c\u003c 0.5%\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eUser interface\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eResistive touch display, also usable with wet gloves\u003c\/li\u003e\u003cli\u003eBacklit buttons: Home, Stop Infusion, On\/Off\u003c\/li\u003e\u003cli\u003eMenu in Italian with text messages and guidance images\u003c\/li\u003e\u003cli\u003eProgram retention in case of shutdown with pause function\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eDisplay\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e5.1” TFT-LCD resistive Color Touch display\u003c\/li\u003e\u003cli\u003eResolution: 800 × 240\u003c\/li\u003e\u003cli\u003eAutomatic brightness (sensor) or manual\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eAlways visible parameters\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eInfusion in progress, mains\/battery power, battery status, infusion progress\u003c\/li\u003e\u003cli\u003ePressure: cut-off (P1–P9) and current pressure in mmHg\u003c\/li\u003e\u003cli\u003eDrug\/active ingredient name and concentration (if drug library)\u003c\/li\u003e\u003cli\u003eInfusion profile, speed\/dose with unit, remaining duration, remaining volume\u003c\/li\u003e\u003cli\u003eText alarms, pause duration, infused volume (partial and total) with memory retention\u003c\/li\u003e\u003cli\u003eInfused quantity (partial and total), duration (partial and total), Wi-Fi active\/inactive\u003c\/li\u003e\u003cli\u003eLinear barcode or QR code accessible from the menu\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eSpecial functions\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eDose Calculation\u003c\/strong\u003e: automatic speed calculation from dose (µg, mg, IU, mmol) based on weight and\/or time; bolus with automatic speed calculation\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHospital Drug Library\u003c\/strong\u003e:    \u003cul\u003e\u003cli\u003eMax 10,000 drugs with international color code based on ISO 26825\/2020\u003c\/li\u003e\u003cli\u003eMax 32 user-defined categories\u003c\/li\u003e\u003cli\u003eMax 32 patient profiles\u003c\/li\u003e\u003cli\u003eMax 31 care areas\u003c\/li\u003e\u003cli\u003eHard\/soft limits to prevent incorrect dosing with on-screen alerts\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003ePause (stand-by)\u003c\/strong\u003e: 1 min – 24 h; at the end of the pause it re-proposes the last set parameters\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eKVO\u003c\/strong\u003e:    \u003cul\u003e\u003cli\u003eSpeed = 10 ml\/h: KVO 3 ml\/h\u003c\/li\u003e\u003cli\u003eSpeed \u003c 10 ml\/h: KVO 1 ml\/h\u003c\/li\u003e\u003cli\u003eSpeed \u003c 1 ml\/h: KVO = set speed\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eAutoprogramming\u003c\/strong\u003e: verifies the “right therapy for the right patient” by scanning the barcode of syringe\/bottle, pump, patient and operator\u003c\/li\u003e\u003c\/ul\u003e\u003ch4\u003eDoor and free-flow prevention\u003c\/h4\u003e\u003cul\u003e\u003cli\u003eAutomatic door opening\/closing to prevent accidental openings and ensure correct insertion of the infusion set\u003c\/li\u003e\u003cli\u003e3 protection systems against free flow\/accidental boluses:    \u003cul\u003e\u003cli\u003eIntegrated free-flow prevention clamp in the pump: pinches the infusion set during insertion\u003c\/li\u003e\u003cli\u003eClamp integrated in the Infusomat Space Line infusion set: pinches during removal\u003c\/li\u003e\u003cli\u003eBack-off function (peristaltic retraction) for automatic bolus reduction after occlusion\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"B.BRAUN","offers":[{"title":"Default Title","offer_id":57603374481790,"sku":"BB772079","price":2982.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0959\/4873\/4846\/files\/BB772079_--_000_43594.jpg?v=1783426752","url":"https:\/\/www.securlab.it\/en\/products\/b-braun-spaceplus-infusomat-peristaltic-volumetric-pump","provider":"Securlab","version":"1.0","type":"link"}