{"product_id":"incubatore-icf-200-new-a-ventilazione-forzata","title":"ICF 200 NEW Forced Ventilation Incubator","description":"\u003cp\u003e\u003c\/p\u003e\u003ch3 data-end=\"55\" data-start=\"0\"\u003e\u003cstrong data-end=\"53\" data-start=\"4\"\u003eICF 200 NEW Forced Ventilation Incubator\u003c\/strong\u003e\u003c\/h3\u003e\u003ch4 data-end=\"79\" data-start=\"57\"\u003e\u003cstrong data-end=\"77\" data-start=\"62\"\u003eDescription\u003c\/strong\u003e\u003c\/h4\u003e\u003cp data-end=\"573\" data-start=\"80\"\u003eThe \u003cstrong data-end=\"131\" data-start=\"82\"\u003eICF 200 NEW forced ventilation incubator\u003c\/strong\u003e by ArgoLab is designed to ensure \u003cstrong data-end=\"223\" data-start=\"170\"\u003eprecise and uniform temperature control\u003c\/strong\u003e, with a ventilation system adjustable on three levels and a \u003cstrong data-end=\"327\" data-start=\"287\"\u003esterilization program at 130°C\u003c\/strong\u003e. Thanks to the double door with inner glass, samples can be observed without heat loss. Data logging and intuitive operation make it an ideal solution for laboratories that require precision and efficiency.\u003c\/p\u003e\u003ch4 data-end=\"612\" data-start=\"575\"\u003e\u003cstrong data-end=\"610\" data-start=\"580\"\u003eMain features\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"1103\" data-start=\"613\"\u003e\u003cli data-end=\"653\" data-start=\"613\"\u003e\u003cstrong data-end=\"635\" data-start=\"615\"\u003eOperating range:\u003c\/strong\u003e +5°C Ta … +80°C\u003c\/li\u003e\u003cli data-end=\"726\" data-start=\"654\"\u003e\u003cstrong data-end=\"687\" data-start=\"656\"\u003eBacklit LED display\u003c\/strong\u003e for clear reading of parameters\u003c\/li\u003e\u003cli data-end=\"785\" data-start=\"727\"\u003e\u003cstrong data-end=\"761\" data-start=\"729\"\u003eData logging and download\u003c\/strong\u003e via USB flash drive\u003c\/li\u003e\u003cli data-end=\"1002\" data-start=\"786\"\u003e\u003cstrong data-end=\"816\" data-start=\"788\"\u003eAdvanced programming:\u003c\/strong\u003e\u003cul data-end=\"1002\" data-start=\"821\"\u003e\u003cli data-end=\"870\" data-start=\"821\"\u003e8 programmable programs with 8 steps each\u003c\/li\u003e\u003cli data-end=\"907\" data-start=\"873\"\u003eBasic single-step program\u003c\/li\u003e\u003cli data-end=\"949\" data-start=\"910\"\u003eMulti-step program up to 64 steps\u003c\/li\u003e\u003cli data-end=\"1002\" data-start=\"952\"\u003eSpecial program for sterilization at 130°C\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"1103\" data-start=\"1003\"\u003e\u003cstrong data-end=\"1032\" data-start=\"1005\"\u003eAdjustable ventilation\u003c\/strong\u003e on three levels:\u003cul data-end=\"1103\" data-start=\"1053\"\u003e\u003cli data-end=\"1068\" data-start=\"1053\"\u003eHigh = 100%\u003c\/li\u003e\u003cli data-end=\"1087\" data-start=\"1071\"\u003eMedium = 75%\u003c\/li\u003e\u003cli data-end=\"1103\" data-start=\"1090\"\u003eLow = 50%\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"1133\" data-start=\"1105\"\u003e\u003cstrong data-end=\"1131\" data-start=\"1110\"\u003eAdvanced functions\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"1852\" data-start=\"1134\"\u003e\u003cli data-end=\"1206\" data-start=\"1134\"\u003e\u003cstrong data-end=\"1166\" data-start=\"1136\"\u003eSimultaneous display\u003c\/strong\u003e of all operating parameters\u003c\/li\u003e\u003cli data-end=\"1268\" data-start=\"1207\"\u003e\u003cstrong data-end=\"1238\" data-start=\"1209\"\u003eVisual and acoustic alarms\u003c\/strong\u003e muteable by the operator\u003c\/li\u003e\u003cli data-end=\"1353\" data-start=\"1269\"\u003e\u003cstrong data-end=\"1290\" data-start=\"1271\"\u003eDigital timer:\u003c\/strong\u003e from 1 minute to 99 hours and 59 minutes, with continuous operation\u003c\/li\u003e\u003cli data-end=\"1432\" data-start=\"1354\"\u003e\u003cstrong data-end=\"1378\" data-start=\"1356\"\u003eDelayed start\u003c\/strong\u003e to program the start of the heating cycle\u003c\/li\u003e\u003cli data-end=\"1499\" data-start=\"1433\"\u003e\u003cstrong data-end=\"1466\" data-start=\"1435\"\u003eSafe temperature function\u003c\/strong\u003e for sample protection\u003c\/li\u003e\u003cli data-end=\"1568\" data-start=\"1500\"\u003e\u003cstrong data-end=\"1530\" data-start=\"1502\"\u003eSterilization cycle\u003c\/strong\u003e at 130°C for a maximum of 10 minutes\u003c\/li\u003e\u003cli data-end=\"1660\" data-start=\"1569\"\u003e\u003cstrong data-end=\"1604\" data-start=\"1571\"\u003eWorking data logging:\u003c\/strong\u003e up to 2167 values, with USB download capability\u003c\/li\u003e\u003cli data-end=\"1749\" data-start=\"1661\"\u003e\u003cstrong data-end=\"1689\" data-start=\"1663\"\u003eEnergy efficiency:\u003c\/strong\u003e reduced heating times and low energy consumption\u003c\/li\u003e\u003cli data-end=\"1852\" data-start=\"1750\"\u003e\u003cstrong data-end=\"1792\" data-start=\"1752\"\u003eSafety class 3.1 (DIN 12880):\u003c\/strong\u003e fluid-expansion maximum temperature controller\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"1883\" data-start=\"1854\"\u003e\u003cstrong data-end=\"1881\" data-start=\"1859\"\u003eStructure and Design\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2279\" data-start=\"1884\"\u003e\u003cli data-end=\"1984\" data-start=\"1884\"\u003e\u003cstrong data-end=\"1923\" data-start=\"1886\"\u003eDouble door with glass interior\u003c\/strong\u003e for observing samples without heat loss\u003c\/li\u003e\u003cli data-end=\"2055\" data-start=\"1985\"\u003e\u003cstrong data-end=\"2015\" data-start=\"1987\"\u003eØ 5 mm pass-through hole\u003c\/strong\u003e for inserting an external sensor\u003c\/li\u003e\u003cli data-end=\"2136\" data-start=\"2056\"\u003e\u003cstrong data-end=\"2084\" data-start=\"2058\"\u003eStainless steel chamber\u003c\/strong\u003e with rounded corners for easier cleaning\u003c\/li\u003e\u003cli data-end=\"2205\" data-start=\"2137\"\u003e\u003cstrong data-end=\"2178\" data-start=\"2139\"\u003eAnti-tip supports and shelves\u003c\/strong\u003e completely removable\u003c\/li\u003e\u003cli data-end=\"2279\" data-start=\"2206\"\u003e\u003cstrong data-end=\"2230\" data-start=\"2208\"\u003eDoor switch\u003c\/strong\u003e to facilitate loading and unloading of samples\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2304\" data-start=\"2281\"\u003e\u003cstrong data-end=\"2302\" data-start=\"2286\"\u003eTechnical data\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2605\" data-start=\"2305\"\u003e\u003cli data-end=\"2332\" data-start=\"2305\"\u003e\u003cstrong data-end=\"2320\" data-start=\"2307\"\u003eCapacity:\u003c\/strong\u003e 200 liters\u003c\/li\u003e\u003cli data-end=\"2374\" data-start=\"2333\"\u003e\u003cstrong data-end=\"2366\" data-start=\"2335\"\u003eMaximum shelf load:\u003c\/strong\u003e 20 kg\u003c\/li\u003e\u003cli data-end=\"2433\" data-start=\"2375\"\u003e\u003cstrong data-end=\"2412\" data-start=\"2377\"\u003eExternal dimensions (W x D x H):\u003c\/strong\u003e 945 x 825 x 870 mm\u003c\/li\u003e\u003cli data-end=\"2492\" data-start=\"2434\"\u003e\u003cstrong data-end=\"2471\" data-start=\"2436\"\u003eInternal dimensions (W x D x H):\u003c\/strong\u003e 645 x 495 x 650 mm\u003c\/li\u003e\u003cli data-end=\"2513\" data-start=\"2493\"\u003e\u003cstrong data-end=\"2504\" data-start=\"2495\"\u003eWeight:\u003c\/strong\u003e 103 kg\u003c\/li\u003e\u003cli data-end=\"2546\" data-start=\"2514\"\u003e\u003cstrong data-end=\"2538\" data-start=\"2516\"\u003ePower consumption:\u003c\/strong\u003e 700 W\u003c\/li\u003e\u003cli data-end=\"2576\" data-start=\"2547\"\u003e\u003cstrong data-end=\"2563\" data-start=\"2549\"\u003eFrequency:\u003c\/strong\u003e 50 - 60 Hz\u003c\/li\u003e\u003cli data-end=\"2605\" data-start=\"2577\"\u003e\u003cstrong data-end=\"2597\" data-start=\"2579\"\u003ePower supply:\u003c\/strong\u003e 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2641\" data-start=\"2607\"\u003e\u003cstrong data-end=\"2639\" data-start=\"2612\"\u003ePerformance and Safety\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2869\" data-start=\"2642\"\u003e\u003cli data-end=\"2690\" data-start=\"2642\"\u003e\u003cstrong data-end=\"2678\" data-start=\"2644\"\u003eHeating time at 37°C:\u003c\/strong\u003e 45 minutes\u003c\/li\u003e\u003cli data-end=\"2737\" data-start=\"2691\"\u003e\u003cstrong data-end=\"2727\" data-start=\"2693\"\u003eTemperature variation at 37°C:\u003c\/strong\u003e ± 0,2°C\u003c\/li\u003e\u003cli data-end=\"2790\" data-start=\"2738\"\u003e\u003cstrong data-end=\"2780\" data-start=\"2740\"\u003eTemperature uniformity at 37°C:\u003c\/strong\u003e ± 0,4°C\u003c\/li\u003e\u003cli data-end=\"2869\" data-start=\"2791\"\u003e\u003cstrong data-end=\"2835\" data-start=\"2793\"\u003eOvertemperature safety system:\u003c\/strong\u003e electronic and electromechanical\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2900\" data-start=\"2871\"\u003e\u003cstrong data-end=\"2898\" data-start=\"2876\"\u003eStandard equipment\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"3170\" data-start=\"2901\"\u003e\u003cli data-end=\"3020\" data-start=\"2901\"\u003e\u003cstrong data-end=\"2936\" data-start=\"2903\"\u003eGrated steel shelves:\u003c\/strong\u003e\u003cul data-end=\"3020\" data-start=\"2941\"\u003e\u003cli data-end=\"2982\" data-start=\"2941\"\u003e2 shelves for models up to 55 liters\u003c\/li\u003e\u003cli data-end=\"3020\" data-start=\"2985\"\u003e3 shelves for larger models\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"3099\" data-start=\"3021\"\u003e\u003cstrong data-end=\"3054\" data-start=\"3023\"\u003eCalibration report at 37°C\u003c\/strong\u003e with traceable Accredia reference instrument\u003c\/li\u003e\u003cli data-end=\"3170\" data-start=\"3100\"\u003e\u003cstrong data-end=\"3119\" data-start=\"3102\"\u003eUSB flash drive\u003c\/strong\u003e for data logging and transfer\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"3207\" data-start=\"3172\"\u003e\u003cstrong data-end=\"3205\" data-start=\"3177\"\u003eReference standards\u003c\/strong\u003e\u003c\/h4\u003e\u003cp data-end=\"3329\" data-start=\"3208\"\u003eComplies with directives \u003cstrong data-end=\"3246\" data-start=\"3232\"\u003e2006\/95\/EC\u003c\/strong\u003e, \u003cstrong data-end=\"3263\" data-start=\"3248\"\u003e2004\/108\/EC\u003c\/strong\u003e, \u003cstrong data-end=\"3283\" data-start=\"3265\"\u003eEN61326-1:2006\u003c\/strong\u003e, \u003cstrong data-end=\"3303\" data-start=\"3285\"\u003eEN61010-1:2010\u003c\/strong\u003e, \u003cstrong data-end=\"3327\" data-start=\"3305\"\u003eEN61010-2-010:2003\u003c\/strong\u003e\u003c\/p\u003e\u003cp data-end=\"3535\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"3331\"\u003eThe \u003cstrong data-end=\"3359\" data-start=\"3333\"\u003eICF 200 NEW Incubator\u003c\/strong\u003e is an ideal solution for laboratories that need a precise, safe and efficient thermostatic environment, with advanced data logging and sterilization functions.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"GIORGIO BORMAC","offers":[{"title":"Default Title","offer_id":57603353084286,"sku":"GB41100822","price":3821.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0959\/4873\/4846\/files\/GB41100822_--_000_37176.png?v=1782257451","url":"https:\/\/www.securlab.it\/en\/products\/icf-200-new-forced-ventilation-incubator","provider":"Securlab","version":"1.0","type":"link"}