{"product_id":"incubatore-icf-55-new-a-ventilazione-forzata","title":"ICF 55 NEW Forced Ventilation Incubator","description":"\u003ch2\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3 data-end=\"54\" data-start=\"0\"\u003e\u003cstrong data-end=\"52\" data-start=\"4\"\u003eICF 55 NEW Forced Ventilation Incubator\u003c\/strong\u003e\u003c\/h3\u003e\u003ch4 data-end=\"78\" data-start=\"56\"\u003e\u003cstrong data-end=\"76\" data-start=\"61\"\u003eDescription\u003c\/strong\u003e\u003c\/h4\u003e\u003cp data-end=\"556\" data-start=\"79\"\u003eArgoLab's \u003cstrong data-end=\"129\" data-start=\"81\"\u003eICF 55 NEW forced ventilation incubator\u003c\/strong\u003e is designed to ensure precise temperature control in laboratory applications. Equipped with a ventilation system adjustable on three levels and a \u003cstrong data-end=\"350\" data-start=\"310\"\u003e130°C sterilization program\u003c\/strong\u003e, it offers high performance, advanced safety, and an intuitive interface for optimal management. The double door with glass interior allows observation of samples without heat loss.\u003c\/p\u003e\u003ch4 data-end=\"595\" data-start=\"558\"\u003e\u003cstrong data-end=\"593\" data-start=\"563\"\u003eMain features\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"1094\" data-start=\"596\"\u003e\u003cli data-end=\"636\" data-start=\"596\"\u003e\u003cstrong data-end=\"618\" data-start=\"598\"\u003eWorking range:\u003c\/strong\u003e +5°C Ta … +80°C\u003c\/li\u003e\u003cli data-end=\"717\" data-start=\"637\"\u003e\u003cstrong data-end=\"670\" data-start=\"639\"\u003eBacklit LED display\u003c\/strong\u003e for clear viewing of parameters\u003c\/li\u003e\u003cli data-end=\"776\" data-start=\"718\"\u003e\u003cstrong data-end=\"752\" data-start=\"720\"\u003eData logging and download\u003c\/strong\u003e via USB flash drive\u003c\/li\u003e\u003cli data-end=\"993\" data-start=\"777\"\u003e\u003cstrong data-end=\"807\" data-start=\"779\"\u003eAdvanced programming:\u003c\/strong\u003e\u003cul data-end=\"993\" data-start=\"812\"\u003e\u003cli data-end=\"861\" data-start=\"812\"\u003e8 programmable programs with 8 steps each\u003c\/li\u003e\u003cli data-end=\"898\" data-start=\"864\"\u003eBasic single-step program\u003c\/li\u003e\u003cli data-end=\"940\" data-start=\"901\"\u003eMulti-step program up to 64 steps\u003c\/li\u003e\u003cli data-end=\"993\" data-start=\"943\"\u003eSpecial program for sterilization at 130°C\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"1094\" data-start=\"994\"\u003e\u003cstrong data-end=\"1023\" data-start=\"996\"\u003eAdjustable ventilation\u003c\/strong\u003e on three levels:\u003cul data-end=\"1094\" data-start=\"1044\"\u003e\u003cli data-end=\"1059\" data-start=\"1044\"\u003eHigh = 100%\u003c\/li\u003e\u003cli data-end=\"1078\" data-start=\"1062\"\u003eMedium = 75%\u003c\/li\u003e\u003cli data-end=\"1094\" data-start=\"1081\"\u003eLow = 50%\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"1124\" data-start=\"1096\"\u003e\u003cstrong data-end=\"1122\" data-start=\"1101\"\u003eAdvanced functions\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"1841\" data-start=\"1125\"\u003e\u003cli data-end=\"1197\" data-start=\"1125\"\u003e\u003cstrong data-end=\"1157\" data-start=\"1127\"\u003eSimultaneous display\u003c\/strong\u003e of all operating parameters\u003c\/li\u003e\u003cli data-end=\"1257\" data-start=\"1198\"\u003e\u003cstrong data-end=\"1229\" data-start=\"1200\"\u003eVisual and acoustic alarms\u003c\/strong\u003e can be silenced by the operator\u003c\/li\u003e\u003cli data-end=\"1342\" data-start=\"1258\"\u003e\u003cstrong data-end=\"1279\" data-start=\"1260\"\u003eDigital timer:\u003c\/strong\u003e from 1 minute to 99 hours and 59 minutes, with continuous operation\u003c\/li\u003e\u003cli data-end=\"1421\" data-start=\"1343\"\u003e\u003cstrong data-end=\"1367\" data-start=\"1345\"\u003eDelayed start\u003c\/strong\u003e to program the start of the heating cycle\u003c\/li\u003e\u003cli data-end=\"1488\" data-start=\"1422\"\u003e\u003cstrong data-end=\"1455\" data-start=\"1424\"\u003eSafe temperature function\u003c\/strong\u003e for sample protection\u003c\/li\u003e\u003cli data-end=\"1557\" data-start=\"1489\"\u003e\u003cstrong data-end=\"1519\" data-start=\"1491\"\u003eSterilization cycle\u003c\/strong\u003e at 130°C for a maximum of 10 minutes\u003c\/li\u003e\u003cli data-end=\"1649\" data-start=\"1558\"\u003e\u003cstrong data-end=\"1593\" data-start=\"1560\"\u003eWorking data logging:\u003c\/strong\u003e up to 2167 values, with USB download capability\u003c\/li\u003e\u003cli data-end=\"1738\" data-start=\"1650\"\u003e\u003cstrong data-end=\"1678\" data-start=\"1652\"\u003eEnergy efficiency:\u003c\/strong\u003e reduced heating times and low energy consumption\u003c\/li\u003e\u003cli data-end=\"1841\" data-start=\"1739\"\u003e\u003cstrong data-end=\"1781\" data-start=\"1741\"\u003eSafety class 3.1 (DIN 12880):\u003c\/strong\u003e fluid-expansion maximum temperature controller\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"1872\" data-start=\"1843\"\u003e\u003cstrong data-end=\"1870\" data-start=\"1848\"\u003eStructure and Design\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2268\" data-start=\"1873\"\u003e\u003cli data-end=\"1973\" data-start=\"1873\"\u003e\u003cstrong data-end=\"1912\" data-start=\"1875\"\u003eDouble door with glass interior\u003c\/strong\u003e for observing samples without heat loss\u003c\/li\u003e\u003cli data-end=\"2044\" data-start=\"1974\"\u003e\u003cstrong data-end=\"2004\" data-start=\"1976\"\u003eØ 5 mm pass-through hole\u003c\/strong\u003e for inserting an external sensor\u003c\/li\u003e\u003cli data-end=\"2125\" data-start=\"2045\"\u003e\u003cstrong data-end=\"2073\" data-start=\"2047\"\u003eStainless steel chamber\u003c\/strong\u003e with rounded corners for easier cleaning\u003c\/li\u003e\u003cli data-end=\"2194\" data-start=\"2126\"\u003e\u003cstrong data-end=\"2167\" data-start=\"2128\"\u003eAnti-tip supports and shelves\u003c\/strong\u003e completely removable\u003c\/li\u003e\u003cli data-end=\"2268\" data-start=\"2195\"\u003e\u003cstrong data-end=\"2219\" data-start=\"2197\"\u003eDoor switch\u003c\/strong\u003e to facilitate loading and unloading of samples\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2293\" data-start=\"2270\"\u003e\u003cstrong data-end=\"2291\" data-start=\"2275\"\u003eTechnical data\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2592\" data-start=\"2294\"\u003e\u003cli data-end=\"2320\" data-start=\"2294\"\u003e\u003cstrong data-end=\"2309\" data-start=\"2296\"\u003eCapacity:\u003c\/strong\u003e 57 liters\u003c\/li\u003e\u003cli data-end=\"2362\" data-start=\"2321\"\u003e\u003cstrong data-end=\"2354\" data-start=\"2323\"\u003eMaximum shelf load:\u003c\/strong\u003e 20 kg\u003c\/li\u003e\u003cli data-end=\"2421\" data-start=\"2363\"\u003e\u003cstrong data-end=\"2400\" data-start=\"2365\"\u003eExternal dimensions (W x D x H):\u003c\/strong\u003e 690 x 620 x 650 mm\u003c\/li\u003e\u003cli data-end=\"2480\" data-start=\"2422\"\u003e\u003cstrong data-end=\"2459\" data-start=\"2424\"\u003eInternal dimensions (W x D x H):\u003c\/strong\u003e 400 x 350 x 415 mm\u003c\/li\u003e\u003cli data-end=\"2500\" data-start=\"2481\"\u003e\u003cstrong data-end=\"2492\" data-start=\"2483\"\u003eWeight:\u003c\/strong\u003e 56 kg\u003c\/li\u003e\u003cli data-end=\"2533\" data-start=\"2501\"\u003e\u003cstrong data-end=\"2525\" data-start=\"2503\"\u003ePower consumption:\u003c\/strong\u003e 350 W\u003c\/li\u003e\u003cli data-end=\"2563\" data-start=\"2534\"\u003e\u003cstrong data-end=\"2550\" data-start=\"2536\"\u003eFrequency:\u003c\/strong\u003e 50 - 60 Hz\u003c\/li\u003e\u003cli data-end=\"2592\" data-start=\"2564\"\u003e\u003cstrong data-end=\"2584\" data-start=\"2566\"\u003ePower supply:\u003c\/strong\u003e 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2628\" data-start=\"2594\"\u003e\u003cstrong data-end=\"2626\" data-start=\"2599\"\u003ePerformance and Safety\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2856\" data-start=\"2629\"\u003e\u003cli data-end=\"2677\" data-start=\"2629\"\u003e\u003cstrong data-end=\"2665\" data-start=\"2631\"\u003eHeating time at 37°C:\u003c\/strong\u003e 30 minutes\u003c\/li\u003e\u003cli data-end=\"2724\" data-start=\"2678\"\u003e\u003cstrong data-end=\"2714\" data-start=\"2680\"\u003eTemperature variation at 37°C:\u003c\/strong\u003e ± 0.1°C\u003c\/li\u003e\u003cli data-end=\"2777\" data-start=\"2725\"\u003e\u003cstrong data-end=\"2767\" data-start=\"2727\"\u003eTemperature uniformity at 37°C:\u003c\/strong\u003e ± 0.3°C\u003c\/li\u003e\u003cli data-end=\"2856\" data-start=\"2778\"\u003e\u003cstrong data-end=\"2822\" data-start=\"2780\"\u003eOvertemperature safety system:\u003c\/strong\u003e electronic and electromechanical\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2887\" data-start=\"2858\"\u003e\u003cstrong data-end=\"2885\" data-start=\"2863\"\u003eStandard equipment\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"3157\" data-start=\"2888\"\u003e\u003cli data-end=\"3007\" data-start=\"2888\"\u003e\u003cstrong data-end=\"2923\" data-start=\"2890\"\u003eGrated steel shelves:\u003c\/strong\u003e\u003cul data-end=\"3007\" data-start=\"2928\"\u003e\u003cli data-end=\"2969\" data-start=\"2928\"\u003e2 shelves for models up to 55 liters\u003c\/li\u003e\u003cli data-end=\"3007\" data-start=\"2972\"\u003e3 shelves for larger models\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"3086\" data-start=\"3008\"\u003e\u003cstrong data-end=\"3041\" data-start=\"3010\"\u003eCalibration report at 37°C\u003c\/strong\u003e with traceable Accredia reference instrument\u003c\/li\u003e\u003cli data-end=\"3157\" data-start=\"3087\"\u003e\u003cstrong data-end=\"3106\" data-start=\"3089\"\u003eUSB flash drive\u003c\/strong\u003e for data logging and transfer\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"3194\" data-start=\"3159\"\u003e\u003cstrong data-end=\"3192\" data-start=\"3164\"\u003eApplicable standards\u003c\/strong\u003e\u003c\/h4\u003e\u003cp data-end=\"3316\" data-start=\"3195\"\u003eComplies with directives \u003cstrong data-end=\"3233\" data-start=\"3219\"\u003e2006\/95\/EC\u003c\/strong\u003e, \u003cstrong data-end=\"3250\" data-start=\"3235\"\u003e2004\/108\/EC\u003c\/strong\u003e, \u003cstrong data-end=\"3270\" data-start=\"3252\"\u003eEN61326-1:2006\u003c\/strong\u003e, \u003cstrong data-end=\"3290\" data-start=\"3272\"\u003eEN61010-1:2010\u003c\/strong\u003e, \u003cstrong data-end=\"3314\" data-start=\"3292\"\u003eEN61010-2-010:2003\u003c\/strong\u003e\u003c\/p\u003e\u003cp data-end=\"3521\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"3318\"\u003eThe \u003cstrong data-end=\"3345\" data-start=\"3320\"\u003eICF 55 NEW Incubator\u003c\/strong\u003e is an ideal solution for laboratories that require a precise, safe, and efficient thermostatic environment, with advanced data logging and sterilization functions.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e","brand":"GIORGIO BORMAC","offers":[{"title":"Default Title","offer_id":57603354034558,"sku":"GB41100802","price":1508.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0959\/4873\/4846\/files\/GB41100802_--_000_42976.jpg?v=1782257450","url":"https:\/\/www.securlab.it\/en\/products\/icf-55-new-forced-ventilation-incubator","provider":"Securlab","version":"1.0","type":"link"}