{"product_id":"incubatore-icn-16-new-a-convezione-naturale-vol-16-litri","title":"ICN 16 NEW Incubator with Natural Convection, 16 liters","description":"\u003cp\u003e\u003c\/p\u003e\u003ch3 data-end=\"53\" data-start=\"0\"\u003e\u003cstrong data-end=\"51\" data-start=\"4\"\u003eICN 16 NEW Natural Convection Incubator\u003c\/strong\u003e\u003c\/h3\u003e\u003cp data-end=\"76\" data-start=\"54\"\u003e\u003cstrong data-end=\"65\" data-start=\"54\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch4 data-end=\"100\" data-start=\"78\"\u003e\u003cstrong data-end=\"98\" data-start=\"83\"\u003eDescription\u003c\/strong\u003e\u003c\/h4\u003e\u003cp data-end=\"617\" data-start=\"101\"\u003eThe \u003cstrong data-end=\"150\" data-start=\"103\"\u003eICN 16 NEW natural convection incubator\u003c\/strong\u003e by ArgoLab is designed to ensure precise and reliable temperature control, ideal for laboratories that require stable incubation without the use of forced ventilation. Thanks to its \u003cstrong data-end=\"400\" data-start=\"359\"\u003edoor with a large glass window\u003c\/strong\u003e, it allows samples to be observed without heat loss. The \u003cstrong data-end=\"506\" data-start=\"477\"\u003eUSB data logging\u003c\/strong\u003e system and advanced programming make it a technologically advanced solution for routine applications.\u003c\/p\u003e\u003ch4 data-end=\"656\" data-start=\"619\"\u003e\u003cstrong data-end=\"654\" data-start=\"624\"\u003eMain features\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"1089\" data-start=\"657\"\u003e\u003cli data-end=\"697\" data-start=\"657\"\u003e\u003cstrong data-end=\"679\" data-start=\"659\"\u003eWorking range:\u003c\/strong\u003e +5°C Ta … +70°C\u003c\/li\u003e\u003cli data-end=\"778\" data-start=\"698\"\u003e\u003cstrong data-end=\"731\" data-start=\"700\"\u003eBacklit LED display\u003c\/strong\u003e for clear viewing of parameters\u003c\/li\u003e\u003cli data-end=\"837\" data-start=\"779\"\u003e\u003cstrong data-end=\"813\" data-start=\"781\"\u003eData logging and download\u003c\/strong\u003e via USB flash drive\u003c\/li\u003e\u003cli data-end=\"1001\" data-start=\"838\"\u003e\u003cstrong data-end=\"868\" data-start=\"840\"\u003eAdvanced programming:\u003c\/strong\u003e\u003cul data-end=\"1001\" data-start=\"873\"\u003e\u003cli data-end=\"922\" data-start=\"873\"\u003e8 programmable programs with 8 steps each\u003c\/li\u003e\u003cli data-end=\"959\" data-start=\"925\"\u003eSingle-step basic program\u003c\/li\u003e\u003cli data-end=\"1001\" data-start=\"962\"\u003eMulti-step program up to 64 steps\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"1089\" data-start=\"1002\"\u003e\u003cstrong data-end=\"1054\" data-start=\"1004\"\u003eNatural convection heating system\u003c\/strong\u003e, ideal for delicate incubations\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"1119\" data-start=\"1091\"\u003e\u003cstrong data-end=\"1117\" data-start=\"1096\"\u003eAdvanced functions\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"1697\" data-start=\"1120\"\u003e\u003cli data-end=\"1192\" data-start=\"1120\"\u003e\u003cstrong data-end=\"1152\" data-start=\"1122\"\u003eSimultaneous display\u003c\/strong\u003e of all operating parameters\u003c\/li\u003e\u003cli data-end=\"1254\" data-start=\"1193\"\u003e\u003cstrong data-end=\"1224\" data-start=\"1195\"\u003eVisual and acoustic alarms\u003c\/strong\u003e that can be silenced by the operator\u003c\/li\u003e\u003cli data-end=\"1339\" data-start=\"1255\"\u003e\u003cstrong data-end=\"1276\" data-start=\"1257\"\u003eDigital timer:\u003c\/strong\u003e from 1 minute to 99 hours and 59 minutes, with continuous operation\u003c\/li\u003e\u003cli data-end=\"1418\" data-start=\"1340\"\u003e\u003cstrong data-end=\"1364\" data-start=\"1342\"\u003eDelayed start\u003c\/strong\u003e to schedule the start of the heating cycle\u003c\/li\u003e\u003cli data-end=\"1485\" data-start=\"1419\"\u003e\u003cstrong data-end=\"1452\" data-start=\"1421\"\u003eSafe temperature function\u003c\/strong\u003e for sample protection\u003c\/li\u003e\u003cli data-end=\"1577\" data-start=\"1486\"\u003e\u003cstrong data-end=\"1521\" data-start=\"1488\"\u003eWorking data logging:\u003c\/strong\u003e up to 2167 values, with USB download capability\u003c\/li\u003e\u003cli data-end=\"1655\" data-start=\"1578\"\u003e\u003cstrong data-end=\"1606\" data-start=\"1580\"\u003eEnergy efficiency:\u003c\/strong\u003e low consumption and reduced heating times\u003c\/li\u003e\u003cli data-end=\"1697\" data-start=\"1656\"\u003e\u003cstrong data-end=\"1695\" data-start=\"1658\"\u003eSafety class 2 (DIN 12880)\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"1728\" data-start=\"1699\"\u003e\u003cstrong data-end=\"1726\" data-start=\"1704\"\u003eStructure and Design\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2056\" data-start=\"1729\"\u003e\u003cli data-end=\"1833\" data-start=\"1729\"\u003e\u003cstrong data-end=\"1772\" data-start=\"1731\"\u003eDoor with large glass window\u003c\/strong\u003e for observing samples without heat loss\u003c\/li\u003e\u003cli data-end=\"1906\" data-start=\"1834\"\u003e\u003cstrong data-end=\"1866\" data-start=\"1836\"\u003ePass-through hole Ø 5.5 mm\u003c\/strong\u003e for inserting an external sensor\u003c\/li\u003e\u003cli data-end=\"1987\" data-start=\"1907\"\u003e\u003cstrong data-end=\"1935\" data-start=\"1909\"\u003eStainless steel chamber\u003c\/strong\u003e with rounded corners for easier cleaning\u003c\/li\u003e\u003cli data-end=\"2056\" data-start=\"1988\"\u003e\u003cstrong data-end=\"2029\" data-start=\"1990\"\u003eAnti-tip supports and shelves\u003c\/strong\u003e fully removable\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2081\" data-start=\"2058\"\u003e\u003cstrong data-end=\"2079\" data-start=\"2063\"\u003eTechnical data\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2378\" data-start=\"2082\"\u003e\u003cli data-end=\"2108\" data-start=\"2082\"\u003e\u003cstrong data-end=\"2097\" data-start=\"2084\"\u003eCapacity:\u003c\/strong\u003e 16 liters\u003c\/li\u003e\u003cli data-end=\"2149\" data-start=\"2109\"\u003e\u003cstrong data-end=\"2142\" data-start=\"2111\"\u003eMaximum shelf load:\u003c\/strong\u003e 5 kg\u003c\/li\u003e\u003cli data-end=\"2208\" data-start=\"2150\"\u003e\u003cstrong data-end=\"2187\" data-start=\"2152\"\u003eExternal dimensions (W x D x H):\u003c\/strong\u003e 530 x 450 x 370 mm\u003c\/li\u003e\u003cli data-end=\"2267\" data-start=\"2209\"\u003e\u003cstrong data-end=\"2246\" data-start=\"2211\"\u003eInternal dimensions (W x D x H):\u003c\/strong\u003e 270 x 255 x 230 mm\u003c\/li\u003e\u003cli data-end=\"2287\" data-start=\"2268\"\u003e\u003cstrong data-end=\"2279\" data-start=\"2270\"\u003eWeight:\u003c\/strong\u003e 23 kg\u003c\/li\u003e\u003cli data-end=\"2319\" data-start=\"2288\"\u003e\u003cstrong data-end=\"2312\" data-start=\"2290\"\u003ePower consumption:\u003c\/strong\u003e 85 W\u003c\/li\u003e\u003cli data-end=\"2349\" data-start=\"2320\"\u003e\u003cstrong data-end=\"2336\" data-start=\"2322\"\u003eFrequency:\u003c\/strong\u003e 50 - 60 Hz\u003c\/li\u003e\u003cli data-end=\"2378\" data-start=\"2350\"\u003e\u003cstrong data-end=\"2370\" data-start=\"2352\"\u003ePower supply:\u003c\/strong\u003e 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2414\" data-start=\"2380\"\u003e\u003cstrong data-end=\"2412\" data-start=\"2385\"\u003ePerformance and Safety\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2622\" data-start=\"2415\"\u003e\u003cli data-end=\"2463\" data-start=\"2415\"\u003e\u003cstrong data-end=\"2451\" data-start=\"2417\"\u003eHeating time at 37°C:\u003c\/strong\u003e 18 minutes\u003c\/li\u003e\u003cli data-end=\"2510\" data-start=\"2464\"\u003e\u003cstrong data-end=\"2500\" data-start=\"2466\"\u003eTemperature variation at 37°C:\u003c\/strong\u003e ± 0.3°C\u003c\/li\u003e\u003cli data-end=\"2563\" data-start=\"2511\"\u003e\u003cstrong data-end=\"2553\" data-start=\"2513\"\u003eTemperature uniformity at 37°C:\u003c\/strong\u003e ± 0.4°C\u003c\/li\u003e\u003cli data-end=\"2622\" data-start=\"2564\"\u003e\u003cstrong data-end=\"2608\" data-start=\"2566\"\u003eOvertemperature safety system:\u003c\/strong\u003e electronic\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2653\" data-start=\"2624\"\u003e\u003cstrong data-end=\"2651\" data-start=\"2629\"\u003eStandard equipment\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2923\" data-start=\"2654\"\u003e\u003cli data-end=\"2773\" data-start=\"2654\"\u003e\u003cstrong data-end=\"2689\" data-start=\"2656\"\u003eGridded steel shelves:\u003c\/strong\u003e\u003cul data-end=\"2773\" data-start=\"2694\"\u003e\u003cli data-end=\"2735\" data-start=\"2694\"\u003e2 shelves for models up to 55 liters\u003c\/li\u003e\u003cli data-end=\"2773\" data-start=\"2738\"\u003e3 shelves for larger models\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"2852\" data-start=\"2774\"\u003e\u003cstrong data-end=\"2807\" data-start=\"2776\"\u003eCalibration report at 37°C\u003c\/strong\u003e with traceable reference instrument Accredia\u003c\/li\u003e\u003cli data-end=\"2923\" data-start=\"2853\"\u003e\u003cstrong data-end=\"2872\" data-start=\"2855\"\u003eUSB flash drive\u003c\/strong\u003e for data logging and transfer\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2960\" data-start=\"2925\"\u003e\u003cstrong data-end=\"2958\" data-start=\"2930\"\u003eReference standards\u003c\/strong\u003e\u003c\/h4\u003e\u003cp data-end=\"3082\" data-start=\"2961\"\u003eCompliant with directives \u003cstrong data-end=\"2999\" data-start=\"2985\"\u003e2006\/95\/EC\u003c\/strong\u003e, \u003cstrong data-end=\"3016\" data-start=\"3001\"\u003e2004\/108\/EC\u003c\/strong\u003e, \u003cstrong data-end=\"3036\" data-start=\"3018\"\u003eEN61326-1:2006\u003c\/strong\u003e, \u003cstrong data-end=\"3056\" data-start=\"3038\"\u003eEN61010-1:2010\u003c\/strong\u003e, \u003cstrong data-end=\"3080\" data-start=\"3058\"\u003eEN61010-2-010:2003\u003c\/strong\u003e\u003c\/p\u003e\u003cp data-end=\"3284\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"3084\"\u003eThe \u003cstrong data-end=\"3111\" data-start=\"3086\"\u003eICN 16 NEW Incubator\u003c\/strong\u003e is a compact and efficient solution for laboratories that require controlled incubations, with a simple interface and advanced data logging features.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"GIORGIO BORMAC","offers":[{"title":"Default Title","offer_id":57603354853758,"sku":"GB41101002","price":883.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0959\/4873\/4846\/files\/GB41101002_--_000_29118.jpg?v=1782257453","url":"https:\/\/www.securlab.it\/en\/products\/icn-16-new-incubator-with-natural-convection-16-liters","provider":"Securlab","version":"1.0","type":"link"}