{"product_id":"fotometro-multiparametro-md-150-cloro-ph-e-acido-cianurico","title":"Multiparameter Photometer MD 150 Chlorine, pH and Cyanuric Acid","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\" data-end=\"311\" data-start=\"181\"\u003eThe \u003cstrong data-end=\"219\" data-start=\"184\"\u003eMD 150 Multi-Parameter Photometer\u003c\/strong\u003e is a professional portable instrument designed for water control and analysis.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp data-end=\"510\" data-start=\"313\"\u003eIt allows the determination of \u003cstrong data-end=\"390\" data-start=\"343\"\u003efree and total chlorine, pH, and cyanuric acid\u003c\/strong\u003e, combining the main measurements required for water quality monitoring in a single device.\u003c\/p\u003e\u003cp data-end=\"789\" data-start=\"512\"\u003eCompact, robust, and simple to use, the MD 150 is equipped with \u003cstrong data-end=\"597\" data-start=\"578\"\u003eIP67 protection\u003c\/strong\u003e, internal memory, and \u003cstrong data-end=\"643\" data-start=\"628\"\u003eNFC and USB-C interfaces\u003c\/strong\u003e for easy data management and transfer. The product is identified by code \u003cstrong data-end=\"750\" data-start=\"738\"\u003e82821103\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-end=\"779\" data-content-reference-start=\"752\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch2 data-end=\"820\" data-section-id=\"d437e9\" data-start=\"791\"\u003eMain Features\u003c\/h2\u003e\u003cul data-end=\"1406\" data-start=\"822\"\u003e\u003cli data-end=\"858\" data-section-id=\"u8lm59\" data-start=\"822\"\u003ePortable multi-parameter photometer\u003c\/li\u003e\u003cli data-end=\"898\" data-section-id=\"1i3g8k\" data-start=\"859\"\u003eAnalysis of \u003cstrong data-end=\"898\" data-start=\"873\"\u003efree and total chlorine\u003c\/strong\u003e\u003c\/li\u003e\u003cli data-end=\"919\" data-section-id=\"xvjh7w\" data-start=\"899\"\u003eAnalysis of \u003cstrong data-end=\"919\" data-start=\"913\"\u003epH\u003c\/strong\u003e\u003c\/li\u003e\u003cli data-end=\"954\" data-section-id=\"1wlprja\" data-start=\"920\"\u003eAnalysis of \u003cstrong data-end=\"954\" data-start=\"935\"\u003ecyanuric acid\u003c\/strong\u003e\u003c\/li\u003e\u003cli data-end=\"987\" data-section-id=\"1ccimpi\" data-start=\"955\"\u003ePhotometric range from 0 to 3 Abs\u003c\/li\u003e\u003cli data-end=\"1019\" data-section-id=\"er8etn\" data-start=\"988\"\u003ePhotometric accuracy 3% FS\u003c\/li\u003e\u003cli data-end=\"1049\" data-section-id=\"goc6vf\" data-start=\"1020\"\u003eBacklit LCD display\u003c\/li\u003e\u003cli data-end=\"1089\" data-section-id=\"6vakqg\" data-start=\"1050\"\u003eInternal memory for 100 data sets\u003c\/li\u003e\u003cli data-end=\"1107\" data-section-id=\"uqeqjs\" data-start=\"1090\"\u003eNFC interface\u003c\/li\u003e\u003cli data-end=\"1128\" data-section-id=\"zia3yo\" data-start=\"1108\"\u003eUSB-C connection\u003c\/li\u003e\u003cli data-end=\"1155\" data-section-id=\"jky0nd\" data-start=\"1129\"\u003eIP67 protection rating\u003c\/li\u003e\u003cli data-end=\"1195\" data-section-id=\"9owogw\" data-start=\"1156\"\u003eLED optics with spectrometric sensor\u003c\/li\u003e\u003cli data-end=\"1249\" data-section-id=\"3jrft4\" data-start=\"1196\"\u003eAdjustment executable by manufacturer and user\u003c\/li\u003e\u003cli data-end=\"1317\" data-section-id=\"uwry4q\" data-start=\"1250\"\u003eBattery life up to approx. 5,000 measurements without backlight\u003c\/li\u003e\u003cli data-end=\"1406\" data-section-id=\"1ctewjc\" data-start=\"1318\"\u003eCompact design suitable for field use. \u003cspan class=\"contents\" data-content-reference-end=\"1387\" data-content-reference-start=\"1359\"\u003e\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2 data-end=\"1431\" data-section-id=\"4kewtb\" data-start=\"1408\"\u003eMeasurable Parameters\u003c\/h2\u003e\u003cp data-end=\"1538\" data-start=\"1433\"\u003eThe MD 150 Photometer allows measurement of the main parameters used in water control:\u003c\/p\u003e\u003cul data-end=\"1649\" data-start=\"1540\"\u003e\u003cli data-end=\"1588\" data-section-id=\"6yx30x\" data-start=\"1540\"\u003e\u003cstrong data-end=\"1568\" data-start=\"1542\"\u003eFree and total chlorine:\u003c\/strong\u003e 0.02 – 6.0 mg\/l Cl2\u003c\/li\u003e\u003cli data-end=\"1629\" data-section-id=\"1rc2g87\" data-start=\"1589\"\u003e\u003cstrong data-end=\"1611\" data-start=\"1591\"\u003eCyanuric acid:\u003c\/strong\u003e 10 – 200 mg\/l CyA\u003c\/li\u003e\u003cli data-end=\"1649\" data-section-id=\"1j69z4m\" data-start=\"1630\"\u003e\u003cstrong data-end=\"1639\" data-start=\"1632\"\u003epH:\u003c\/strong\u003e 6.5 – 8.4\u003c\/li\u003e\u003c\/ul\u003e\u003cp data-end=\"1755\" data-start=\"1651\"\u003eThe instrument's photometric range is between \u003cstrong data-end=\"1716\" data-start=\"1703\"\u003e0 and 3 Abs\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-end=\"1727\" data-content-reference-start=\"1699\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch2 data-end=\"1785\" data-section-id=\"1r5esfl\" data-start=\"1757\"\u003eMeasurement Technology\u003c\/h2\u003e\u003cp data-end=\"1899\" data-start=\"1787\"\u003eThe system uses \u003cstrong data-end=\"1873\" data-start=\"1810\"\u003eLED optics with a spectrometric sensor and anti-interference filter\u003c\/strong\u003e, in the planned variants.\u003c\/p\u003e\u003cp data-end=\"1938\" data-start=\"1901\"\u003eThe available wavelengths are:\u003c\/p\u003e\u003cp data-end=\"1992\" data-start=\"1940\"\u003e\u003cstrong data-end=\"1992\" data-start=\"1940\"\u003e415, 445, 480, 515, 530, 555, 590, 630, and 680 nm.\u003c\/strong\u003e\u003c\/p\u003e\u003cp data-end=\"2156\" data-start=\"1994\"\u003eThis configuration allows the instrument to perform photometric measurements dedicated to the various parameters provided. \u003cspan class=\"contents\" data-content-reference-end=\"2120\" data-content-reference-start=\"2091\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch2 data-end=\"2189\" data-section-id=\"1eg57zt\" data-start=\"2158\"\u003eMemory and Data Transfer\u003c\/h2\u003e\u003cp data-end=\"2349\" data-start=\"2191\"\u003eThe MD 150 has a \u003cstrong data-end=\"2267\" data-start=\"2216\"\u003ecircular internal memory for 100 data sets\u003c\/strong\u003e, useful for storing measurements taken during control activities.\u003c\/p\u003e\u003cp data-end=\"2560\" data-start=\"2351\"\u003eThe \u003cstrong data-end=\"2397\" data-start=\"2382\"\u003eUSB-C and NFC communication interfaces\u003c\/strong\u003e allow for more practical data management and facilitate the transfer of information to compatible devices. \u003cspan class=\"contents\" data-content-reference-end=\"2516\" data-content-reference-start=\"2487\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch2 data-end=\"2589\" data-section-id=\"wu3dtw\" data-start=\"2562\"\u003eIP67 Protection Rating\u003c\/h2\u003e\u003cp data-end=\"2827\" data-start=\"2591\"\u003eThe photometer's structure has an \u003cstrong data-end=\"2658\" data-start=\"2650\"\u003eIP67 protection rating\u003c\/strong\u003e, a particularly useful feature for professional use in environments where the instrument may be exposed to water, humidity, or demanding operating conditions.\u003c\/p\u003e\u003cp data-end=\"2976\" data-start=\"2829\"\u003eThe intended operating range includes temperatures from \u003cstrong data-end=\"2897\" data-start=\"2884\"\u003e5 to 50 °C\u003c\/strong\u003e and relative humidity from \u003cstrong data-end=\"2937\" data-start=\"2921\"\u003e30 to 95% RH\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-end=\"2924\" data-content-reference-start=\"2895\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch2 data-end=\"3000\" data-section-id=\"tcwv77\" data-start=\"2978\"\u003eTechnical Specifications\u003c\/h2\u003e\u003cul data-end=\"3975\" data-start=\"3002\"\u003e\u003cli data-end=\"3023\" data-section-id=\"11yzxb7\" data-start=\"3002\"\u003e\u003cstrong data-end=\"3016\" data-start=\"3004\"\u003eModel:\u003c\/strong\u003e MD 150\u003c\/li\u003e\u003cli data-end=\"3094\" data-section-id=\"qwn2k7\" data-start=\"3024\"\u003e\u003cstrong data-end=\"3051\" data-start=\"3026\"\u003eMeasurable Parameters:\u003c\/strong\u003e Free and total chlorine, pH, Cyanuric Acid\u003c\/li\u003e\u003cli data-end=\"3149\" data-section-id=\"13ehce\" data-start=\"3095\"\u003e\u003cstrong data-end=\"3129\" data-start=\"3097\"\u003eFree and Total Chlorine Range:\u003c\/strong\u003e 0.02 – 6.0 mg\/l Cl2\u003c\/li\u003e\u003cli data-end=\"3196\" data-section-id=\"140jh4\" data-start=\"3150\"\u003e\u003cstrong data-end=\"3178\" data-start=\"3152\"\u003eCyanuric Acid Range:\u003c\/strong\u003e 10 – 200 mg\/l CyA\u003c\/li\u003e\u003cli data-end=\"3222\" data-section-id=\"1xu0rft\" data-start=\"3197\"\u003e\u003cstrong data-end=\"3212\" data-start=\"3199\"\u003epH Range:\u003c\/strong\u003e 6.5 – 8.4\u003c\/li\u003e\u003cli data-end=\"3257\" data-section-id=\"qa72fv\" data-start=\"3223\"\u003e\u003cstrong data-end=\"3247\" data-start=\"3225\"\u003ePhotometric Range:\u003c\/strong\u003e 0 – 3 Abs\u003c\/li\u003e\u003cli data-end=\"3305\" data-section-id=\"1hczkyd\" data-start=\"3258\"\u003e\u003cstrong data-end=\"3288\" data-start=\"3260\"\u003ePhotometric Accuracy:\u003c\/strong\u003e 3% FS at 20–25 °C\u003c\/li\u003e\u003cli data-end=\"3376\" data-section-id=\"pue59o\" data-start=\"3306\"\u003e\u003cstrong data-end=\"3329\" data-start=\"3308\"\u003eWavelengths:\u003c\/strong\u003e 415, 445, 480, 515, 530, 555, 590, 630, 680 nm\u003c\/li\u003e\u003cli data-end=\"3411\" data-section-id=\"10iuskx\" data-start=\"3377\"\u003e\u003cstrong data-end=\"3391\" data-start=\"3379\"\u003eDisplay:\u003c\/strong\u003e Backlit LCD\u003c\/li\u003e\u003cli data-end=\"3466\" data-section-id=\"1mnbeq4\" data-start=\"3412\"\u003e\u003cstrong data-end=\"3426\" data-start=\"3414\"\u003eMemory:\u003c\/strong\u003e circular internal for 100 data sets\u003c\/li\u003e\u003cli data-end=\"3513\" data-section-id=\"zfpn5\" data-start=\"3467\"\u003e\u003cstrong data-end=\"3501\" data-start=\"3469\"\u003eCommunication Interfaces:\u003c\/strong\u003e USB-C \/ NFC\u003c\/li\u003e\u003cli data-end=\"3545\" data-section-id=\"7x6xub\" data-start=\"3514\"\u003e\u003cstrong data-end=\"3540\" data-start=\"3516\"\u003eProtection Rating:\u003c\/strong\u003e IP67\u003c\/li\u003e\u003cli data-end=\"3640\" data-section-id=\"1pgcwqu\" data-start=\"3546\"\u003e\u003cstrong data-end=\"3559\" data-start=\"3548\"\u003eOptics:\u003c\/strong\u003e LED with spectrometric sensor and anti-interference filter, in selected variants\u003c\/li\u003e\u003cli data-end=\"3727\" data-section-id=\"1t2l4vm\" data-start=\"3641\"\u003e\u003cstrong data-end=\"3659\" data-start=\"3643\"\u003eAdjustment:\u003c\/strong\u003e manufacturer and user adjustment, possible at any time\u003c\/li\u003e\u003cli data-end=\"3766\" data-section-id=\"va8fym\" data-start=\"3728\"\u003e\u003cstrong data-end=\"3756\" data-start=\"3730\"\u003eWorking Temperature:\u003c\/strong\u003e 5 – 50 °C\u003c\/li\u003e\u003cli data-end=\"3803\" data-section-id=\"v8aqql\" data-start=\"3767\"\u003e\u003cstrong data-end=\"3791\" data-start=\"3769\"\u003eWorking Humidity:\u003c\/strong\u003e 30 – 95% RH\u003c\/li\u003e\u003cli data-end=\"3869\" data-section-id=\"srvxvj\" data-start=\"3804\"\u003e\u003cstrong data-end=\"3820\" data-start=\"3806\"\u003eBattery Life:\u003c\/strong\u003e approx. 5,000 measurements without backlight\u003c\/li\u003e\u003cli data-end=\"3904\" data-section-id=\"1kky7tm\" data-start=\"3870\"\u003e\u003cstrong data-end=\"3887\" data-start=\"3872\"\u003eDimensions:\u003c\/strong\u003e 155 × 76 × 45 mm\u003c\/li\u003e\u003cli data-end=\"3975\" data-section-id=\"1mcphik\" data-start=\"3905\"\u003e\u003cstrong data-end=\"3927\" data-start=\"3907\"\u003eProduct Code:\u003c\/strong\u003e 82821103. \u003cspan class=\"contents\" data-content-reference-end=\"3914\" data-content-reference-start=\"3886\"\u003e\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2 data-end=\"3992\" data-section-id=\"mslteg\" data-start=\"3977\"\u003eApplications\u003c\/h2\u003e\u003cp data-end=\"4111\" data-start=\"3994\"\u003eThe MD 150 Multi-Parameter Photometer is suitable for professional water control activities, particularly for:\u003c\/p\u003e\u003cul data-end=\"4336\" data-start=\"4113\"\u003e\u003cli data-end=\"4122\" data-section-id=\"olmcjn\" data-start=\"4113\"\u003eswimming pools\u003c\/li\u003e\u003cli data-end=\"4140\" data-section-id=\"1vokvyr\" data-start=\"4123\"\u003esports centers\u003c\/li\u003e\u003cli data-end=\"4165\" data-section-id=\"818hiu\" data-start=\"4141\"\u003eSPAs and wellness centers\u003c\/li\u003e\u003cli data-end=\"4203\" data-section-id=\"8oa8ie\" data-start=\"4166\"\u003ewater treatment plants\u003c\/li\u003e\u003cli data-end=\"4216\" data-section-id=\"14h6oe3\" data-start=\"4204\"\u003elaboratories\u003c\/li\u003e\u003cli data-end=\"4238\" data-section-id=\"ys4wh9\" data-start=\"4217\"\u003ehospitality facilities\u003c\/li\u003e\u003cli data-end=\"4272\" data-section-id=\"dkissp\" data-start=\"4239\"\u003epool maintenance companies\u003c\/li\u003e\u003cli data-end=\"4336\" data-section-id=\"1l3dguf\" data-start=\"4273\"\u003ewater quality control and monitoring activities\u003c\/li\u003e\u003c\/ul\u003e\u003ch2 data-end=\"4349\" data-section-id=\"m56thc\" data-start=\"4338\"\u003eAdvantages\u003c\/h2\u003e\u003cp data-end=\"4498\" data-start=\"4351\"\u003eThe MD 150 allows control of \u003cstrong data-end=\"4438\" data-start=\"4385\"\u003ethree fundamental parameters with a single instrument\u003c\/strong\u003e, reducing the need to use separate devices.\u003c\/p\u003e\u003cp data-end=\"4698\" data-start=\"4500\"\u003eThe combination of \u003cstrong data-end=\"4582\" data-start=\"4520\"\u003eportability, IP67 protection, internal memory, NFC, and USB-C\u003c\/strong\u003e makes it particularly suitable for those who perform frequent checks both in the laboratory and directly in the field.\u003c\/p\u003e\u003ch2 data-end=\"4716\" data-section-id=\"1uu5tuc\" data-start=\"4700\"\u003eProduct Data\u003c\/h2\u003e\u003cp data-end=\"4891\" data-start=\"4718\"\u003e\u003cstrong data-end=\"4731\" data-start=\"4718\"\u003eProduct:\u003c\/strong\u003e MD 150 Multi-Parameter Photometer\u003cbr data-end=\"4766\" data-start=\"4763\"\u003e\u003cstrong data-end=\"4780\" data-start=\"4766\"\u003eParameters:\u003c\/strong\u003e Free and total chlorine, pH, Cyanuric Acid\u003cbr data-end=\"4826\" data-start=\"4823\"\u003e\u003cstrong data-end=\"4837\" data-start=\"4826\"\u003eCode:\u003c\/strong\u003e 82821103\u003cbr data-end=\"4849\" data-start=\"4846\"\u003e\u003cstrong data-end=\"4863\" data-start=\"4849\"\u003eCategory:\u003c\/strong\u003e Photometers for water analysis\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e","brand":"GIORGIO BORMAC","offers":[{"title":"Default Title","offer_id":57985323303294,"sku":"GB82821103","price":854.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0959\/4873\/4846\/files\/GB82821103_--_000_53817.jpg?v=1788790305","url":"https:\/\/www.securlab.it\/en\/products\/multiparameter-photometer-md-150-chlorine-ph-and-cyanuric-acid","provider":"Securlab","version":"1.0","type":"link"}