{"product_id":"pipetman-gilson-multicanale-p8x200-20-200-ul","title":"PIPETMAN Gilson Multichannel P8x200, 20-200 µL","description":"\u003ch2 data-end=\"182\" data-start=\"121\"\u003e\u003cstrong data-end=\"182\" data-start=\"123\"\u003ePIPETMAN® Multichannel Pipette P8X200 – Volume 20–200 µL\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3 data-end=\"199\" data-start=\"184\"\u003eDescription\u003c\/h3\u003e\u003cp data-end=\"501\" data-start=\"200\"\u003ePIPETMAN® is the global standard for reliability, accuracy, and durability in pipetting.\u003cbr data-end=\"291\" data-start=\"288\"\/\u003eThe \u003cstrong data-end=\"313\" data-start=\"303\"\u003eP8X200\u003c\/strong\u003e version is an air-displacement multichannel pipette, with \u003cstrong data-end=\"402\" data-start=\"366\"\u003eadjustable volume from 20 to 200 µL\u003c\/strong\u003e, ideal for laboratory applications that require precision, repeatability, and user comfort.\u003c\/p\u003e\u003cp data-end=\"648\" data-start=\"503\"\u003eMade of \u003cstrong data-end=\"548\" data-start=\"517\"\u003ePVDF and stainless steel\u003c\/strong\u003e, it ensures chemical and mechanical resistance, making it an economical and long-lasting solution.\u003c\/p\u003e\u003ch3 data-end=\"689\" data-start=\"655\"\u003e\u003cstrong data-end=\"689\" data-start=\"659\"\u003eMain features\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-end=\"1367\" data-start=\"690\"\u003e\u003cli data-end=\"758\" data-start=\"690\"\u003e\u003cp data-end=\"758\" data-start=\"692\"\u003e\u003cstrong data-end=\"718\" data-start=\"692\"\u003e8-channel multichannel\u003c\/strong\u003e for fast and uniform pipetting.\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"795\" data-start=\"759\"\u003e\u003cp data-end=\"795\" data-start=\"761\"\u003e\u003cstrong data-end=\"782\" data-start=\"761\"\u003eAdjustable volume\u003c\/strong\u003e 20–200 µL.\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"882\" data-start=\"796\"\u003e\u003cp data-end=\"882\" data-start=\"798\"\u003e\u003cstrong data-end=\"830\" data-start=\"798\"\u003eReduced pipetting forces\u003c\/strong\u003e for comfortable use even for many hours.\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"967\" data-start=\"883\"\u003e\u003cp data-end=\"967\" data-start=\"885\"\u003e\u003cstrong data-end=\"925\" data-start=\"885\"\u003eLegendary accuracy and precision\u003c\/strong\u003e, recognized internationally.\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1021\" data-start=\"968\"\u003e\u003cp data-end=\"1021\" data-start=\"970\"\u003e\u003cstrong data-end=\"994\" data-start=\"970\"\u003eMetal ejector\u003c\/strong\u003e for greater durability.\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1108\" data-start=\"1022\"\u003e\u003cp data-end=\"1108\" data-start=\"1024\"\u003e\u003cstrong data-end=\"1052\" data-start=\"1024\"\u003eAutoclavable components\u003c\/strong\u003e (tip ejector, tip holder, and connecting nut).\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1207\" data-start=\"1109\"\u003e\u003cp data-end=\"1207\" data-start=\"1111\"\u003e\u003cstrong data-end=\"1134\" data-start=\"1111\"\u003eEasy maintenance\u003c\/strong\u003e: design that allows replacement and cleaning of essential parts.\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1284\" data-start=\"1208\"\u003e\u003cp data-end=\"1284\" data-start=\"1210\"\u003e\u003cstrong data-end=\"1234\" data-start=\"1210\"\u003eYellow color code\u003c\/strong\u003e for quick identification of the volume range.\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1367\" data-start=\"1285\"\u003e\u003cp data-end=\"1367\" data-start=\"1287\"\u003e\u003cstrong data-end=\"1304\" data-start=\"1287\"\u003eCompatibility\u003c\/strong\u003e with PIPETMAN DIAMOND tips (D200, D300, DF200ST, DF300ST).\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3 data-end=\"1418\" data-start=\"1374\"\u003e\u003cstrong data-end=\"1418\" data-start=\"1378\"\u003eTechnical specifications – Model P8X200\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-end=\"1660\" data-start=\"1419\"\u003e\u003cli data-end=\"1472\" data-start=\"1419\"\u003e\u003cp data-end=\"1472\" data-start=\"1421\"\u003e\u003cstrong data-end=\"1429\" data-start=\"1421\"\u003eType\u003c\/strong\u003e: manual air-displacement pipette\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1504\" data-start=\"1473\"\u003e\u003cp data-end=\"1504\" data-start=\"1475\"\u003e\u003cstrong data-end=\"1494\" data-start=\"1475\"\u003eNominal volume\u003c\/strong\u003e: 200 µL\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1539\" data-start=\"1505\"\u003e\u003cp data-end=\"1539\" data-start=\"1507\"\u003e\u003cstrong data-end=\"1526\" data-start=\"1507\"\u003eVolume range\u003c\/strong\u003e: 20–200 µL\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1567\" data-start=\"1540\"\u003e\u003cp data-end=\"1567\" data-start=\"1542\"\u003e\u003cstrong data-end=\"1562\" data-start=\"1542\"\u003eNumber of channels\u003c\/strong\u003e: 8\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1597\" data-start=\"1568\"\u003e\u003cp data-end=\"1597\" data-start=\"1570\"\u003e\u003cstrong data-end=\"1591\" data-start=\"1570\"\u003eAdjustable volume\u003c\/strong\u003e: Yes\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1625\" data-start=\"1598\"\u003e\u003cp data-end=\"1625\" data-start=\"1600\"\u003e\u003cstrong data-end=\"1619\" data-start=\"1600\"\u003eProgrammability\u003c\/strong\u003e: No\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1660\" data-start=\"1626\"\u003e\u003cp data-end=\"1660\" data-start=\"1628\"\u003e\u003cstrong data-end=\"1644\" data-start=\"1628\"\u003eConnection\u003c\/strong\u003e: Not connected\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp data-end=\"1704\" data-start=\"1662\"\u003e\u003cstrong data-end=\"1702\" data-start=\"1662\"\u003ePerformance (accuracy and error):\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-end=\"2071\" data-start=\"1705\"\u003e\u003cli data-end=\"1802\" data-start=\"1705\"\u003e\u003cp data-end=\"1737\" data-start=\"1707\"\u003e\u003cstrong data-end=\"1734\" data-start=\"1707\"\u003eSystematic error (µL)\u003c\/strong\u003e:\u003c\/p\u003e\u003cul data-end=\"1802\" data-start=\"1741\"\u003e\u003cli data-end=\"1758\" data-start=\"1741\"\u003e\u003cp data-end=\"1758\" data-start=\"1743\"\u003e20 µL: ± 0.50\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1780\" data-start=\"1762\"\u003e\u003cp data-end=\"1780\" data-start=\"1764\"\u003e100 µL: ± 1.00\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1802\" data-start=\"1784\"\u003e\u003cp data-end=\"1802\" data-start=\"1786\"\u003e200 µL: ± 2.00\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"1896\" data-start=\"1803\"\u003e\u003cp data-end=\"1831\" data-start=\"1805\"\u003e\u003cstrong data-end=\"1829\" data-start=\"1805\"\u003eRandom error (µL):\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-end=\"1896\" data-start=\"1835\"\u003e\u003cli data-end=\"1852\" data-start=\"1835\"\u003e\u003cp data-end=\"1852\" data-start=\"1837\"\u003e20 µL: ≤ 0.25\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1874\" data-start=\"1856\"\u003e\u003cp data-end=\"1874\" data-start=\"1858\"\u003e100 µL: ≤ 0.40\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1896\" data-start=\"1878\"\u003e\u003cp data-end=\"1896\" data-start=\"1880\"\u003e200 µL: ≤ 0.50\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"1983\" data-start=\"1897\"\u003e\u003cp data-end=\"1928\" data-start=\"1899\"\u003e\u003cstrong data-end=\"1925\" data-start=\"1899\"\u003eSystematic error (%)\u003c\/strong\u003e:\u003c\/p\u003e\u003cul data-end=\"1983\" data-start=\"1932\"\u003e\u003cli data-end=\"1946\" data-start=\"1932\"\u003e\u003cp data-end=\"1946\" data-start=\"1934\"\u003e10%: ± 2.5\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1964\" data-start=\"1950\"\u003e\u003cp data-end=\"1964\" data-start=\"1952\"\u003e50%: ± 1.0\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"1983\" data-start=\"1968\"\u003e\u003cp data-end=\"1983\" data-start=\"1970\"\u003e100%: ± 1.0\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"2071\" data-start=\"1984\"\u003e\u003cp data-end=\"2013\" data-start=\"1986\"\u003e\u003cstrong data-end=\"2011\" data-start=\"1986\"\u003eRandom error (%CV):\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-end=\"2071\" data-start=\"2017\"\u003e\u003cli data-end=\"2032\" data-start=\"2017\"\u003e\u003cp data-end=\"2032\" data-start=\"2019\"\u003e10%: ≤ 1.25\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2051\" data-start=\"2036\"\u003e\u003cp data-end=\"2051\" data-start=\"2038\"\u003e50%: ≤ 0.40\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2071\" data-start=\"2055\"\u003e\u003cp data-end=\"2071\" data-start=\"2057\"\u003e100%: ≤ 0.25\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3 data-end=\"2094\" data-start=\"2078\"\u003e\u003cstrong data-end=\"2094\" data-start=\"2082\"\u003eAdvantages\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-end=\"2434\" data-start=\"2095\"\u003e\u003cli data-end=\"2163\" data-start=\"2095\"\u003e\u003cp data-end=\"2163\" data-start=\"2097\"\u003e? \u003cstrong data-end=\"2125\" data-start=\"2099\"\u003ePipetting comfort\u003c\/strong\u003e: reduces hand fatigue.\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2257\" data-start=\"2164\"\u003e\u003cp data-end=\"2257\" data-start=\"2166\"\u003e? \u003cstrong data-end=\"2194\" data-start=\"2168\"\u003eLong-term reliability\u003c\/strong\u003e: built to last even in laboratories with intensive use.\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2345\" data-start=\"2258\"\u003e\u003cp data-end=\"2345\" data-start=\"2260\"\u003e? \u003cstrong data-end=\"2285\" data-start=\"2262\"\u003eEasy maintenance\u003c\/strong\u003e: designed to be cleaned and calibrated with ease.\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2434\" data-start=\"2346\"\u003e\u003cp data-end=\"2434\" data-start=\"2348\"\u003e? \u003cstrong data-end=\"2405\" data-start=\"2350\"\u003eCompatibility with dedicated PIPETMAN DIAMOND tips\u003c\/strong\u003e for maximum precision.\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3 data-end=\"2475\" data-start=\"2441\"\u003e\u003cstrong data-end=\"2475\" data-start=\"2445\"\u003ePackage contents\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-end=\"2555\" data-start=\"2476\"\u003e\u003cli data-end=\"2504\" data-start=\"2476\"\u003e\u003cp data-end=\"2504\" data-start=\"2478\"\u003ePIPETMAN® P8X200 pipette\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2523\" data-start=\"2505\"\u003e\u003cp data-end=\"2523\" data-start=\"2507\"\u003eUser manual\u003c\/p\u003e\u003c\/li\u003e\u003cli data-end=\"2555\" data-start=\"2524\"\u003e\u003cp data-end=\"2555\" data-start=\"2526\"\u003eCalibration certificate\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e \u003c\/p\u003e","brand":"GILSON","offers":[{"title":"Default Title","offer_id":57603294101886,"sku":"F144072","price":878.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0959\/4873\/4846\/files\/F144072_--_000_52190.jpg?v=1783426464","url":"https:\/\/www.securlab.it\/en\/products\/pipetman-gilson-multichannel-p8x200-20-200-l","provider":"Securlab","version":"1.0","type":"link"}