{"product_id":"ossimetro-portatile-sensore-polarografico-da-3-m-xs-oxy-7-vio","title":"Portable oximeter - 3 m polarographic sensor XS Oxy 7 Vio","description":"\u003ch2 class=\"\" data-end=\"225\" data-start=\"152\"\u003e\u003cstrong data-end=\"225\" data-start=\"154\"\u003eXS Oxy 7 Vio - Portable Oximeter with 3 m Polarographic Sensor\u003c\/strong\u003e\u003c\/h2\u003e\u003cp class=\"\" data-end=\"696\" data-start=\"227\"\u003e\u003cstrong data-end=\"242\" data-start=\"227\"\u003eDescription\u003c\/strong\u003e\u003cbr data-end=\"245\" data-start=\"242\"\/\u003eXS Oxy 7 Vio is a professional portable oximeter equipped with a high-definition, backlit color LCD display, perfect for measuring dissolved oxygen (DO), oxygen saturation (O2) and barometric pressure, with simultaneous temperature display.\u003cbr data-end=\"537\" data-start=\"534\"\/\u003eThe on-screen guide during setup and calibration, together with automatic one- or two-point calibration (0% - 100%), ensures simple and immediate use.\u003c\/p\u003e\u003cp class=\"\" data-end=\"971\" data-start=\"698\"\u003eThe device offers automatic temperature and barometric pressure compensation, as well as manual salinity adjustment.\u003cbr data-end=\"842\" data-start=\"839\"\/\u003eIt also includes an automatic sensor polarization timer and a stability indicator with three selectable levels.\u003c\/p\u003e\u003cp class=\"\" data-end=\"1109\" data-start=\"973\"\u003eA colored LED constantly indicates the operating status, supported by an integrated self-diagnosis system for intuitive management.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp class=\"\" data-end=\"1148\" data-start=\"1116\"\u003e\u003cstrong data-end=\"1146\" data-start=\"1116\"\u003eMain features\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-end=\"1713\" data-start=\"1149\"\u003e\u003cli class=\"\" data-end=\"1259\" data-start=\"1149\"\u003e\u003cp class=\"\" data-end=\"1259\" data-start=\"1151\"\u003e\u003cstrong data-end=\"1162\" data-start=\"1151\"\u003eDisplay\u003c\/strong\u003e: high-resolution backlit color LCD with contrast and brightness adjustment.\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1386\" data-start=\"1260\"\u003e\u003cp class=\"\" data-end=\"1282\" data-start=\"1262\"\u003e\u003cstrong data-end=\"1279\" data-start=\"1262\"\u003eCompensation\u003c\/strong\u003e:\u003c\/p\u003e\u003cul data-end=\"1386\" data-start=\"1285\"\u003e\u003cli class=\"\" data-end=\"1322\" data-start=\"1285\"\u003e\u003cp class=\"\" data-end=\"1322\" data-start=\"1287\"\u003eTemperature: automatic and manual\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1362\" data-start=\"1325\"\u003e\u003cp class=\"\" data-end=\"1362\" data-start=\"1327\"\u003eBarometric pressure: automatic\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1386\" data-start=\"1365\"\u003e\u003cp class=\"\" data-end=\"1386\" data-start=\"1367\"\u003eSalinity: manual\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1446\" data-start=\"1387\"\u003e\u003cp class=\"\" data-end=\"1446\" data-start=\"1389\"\u003e\u003cstrong data-end=\"1401\" data-start=\"1389\"\u003eCalibration\u003c\/strong\u003e: automatic on one or two points (0% - 100%)\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1499\" data-start=\"1447\"\u003e\u003cp class=\"\" data-end=\"1499\" data-start=\"1449\"\u003e\u003cstrong data-end=\"1458\" data-start=\"1449\"\u003eTimer\u003c\/strong\u003e: automatic sensor polarization\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1561\" data-start=\"1500\"\u003e\u003cp class=\"\" data-end=\"1561\" data-start=\"1502\"\u003e\u003cstrong data-end=\"1522\" data-start=\"1502\"\u003eMeasurement stability\u003c\/strong\u003e: selection of 3 stability levels\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1618\" data-start=\"1562\"\u003e\u003cp class=\"\" data-end=\"1618\" data-start=\"1564\"\u003e\u003cstrong data-end=\"1580\" data-start=\"1564\"\u003eSelf-diagnosis\u003c\/strong\u003e: status LED and automatic messages\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1640\" data-start=\"1619\"\u003e\u003cp class=\"\" data-end=\"1640\" data-start=\"1621\"\u003e\u003cstrong data-end=\"1634\" data-start=\"1621\"\u003eStandards\u003c\/strong\u003e: CE\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1713\" data-start=\"1641\"\u003e\u003cp class=\"\" data-end=\"1713\" data-start=\"1643\"\u003e\u003cstrong data-end=\"1666\" data-start=\"1643\"\u003eProtection rating\u003c\/strong\u003e: IP57 (resistant to dust and water splashes)\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp class=\"\" data-end=\"1741\" data-start=\"1720\"\u003e\u003cstrong data-end=\"1739\" data-start=\"1720\"\u003eMeasurement ranges\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-end=\"1993\" data-start=\"1742\"\u003e\u003cli class=\"\" data-end=\"1817\" data-start=\"1742\"\u003e\u003cp class=\"\" data-end=\"1817\" data-start=\"1744\"\u003e\u003cem data-end=\"1769\" data-start=\"1744\"\u003eDissolved Oxygen (DO)\u003c\/em\u003e: 0.0 – 50.0 mg\/l, resolution 0.01 \/ 0.1 mg\/l\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1874\" data-start=\"1818\"\u003e\u003cp class=\"\" data-end=\"1874\" data-start=\"1820\"\u003e\u003cem data-end=\"1836\" data-start=\"1820\"\u003eO2 Saturation\u003c\/em\u003e: 0.0 – 400 %, resolution 0.1 \/ 1 %\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1937\" data-start=\"1875\"\u003e\u003cp class=\"\" data-end=\"1937\" data-start=\"1877\"\u003e\u003cem data-end=\"1900\" data-start=\"1877\"\u003eBarometric pressure\u003c\/em\u003e: 0 – 1100 mbar, resolution 1 mbar\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"1993\" data-start=\"1938\"\u003e\u003cp class=\"\" data-end=\"1993\" data-start=\"1940\"\u003e\u003cem data-end=\"1953\" data-start=\"1940\"\u003eTemperature\u003c\/em\u003e: -10.0 – +110.0 °C, resolution ±0.1 °C\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp class=\"\" data-end=\"2017\" data-start=\"2000\"\u003e\u003cstrong data-end=\"2015\" data-start=\"2000\"\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-end=\"2138\" data-start=\"2018\"\u003e\u003cli class=\"\" data-end=\"2057\" data-start=\"2018\"\u003e\u003cp class=\"\" data-end=\"2057\" data-start=\"2020\"\u003eDissolved Oxygen (DO): ±1.5% f.s.\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2082\" data-start=\"2058\"\u003e\u003cp class=\"\" data-end=\"2082\" data-start=\"2060\"\u003eO2 Saturation: ±10%\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2115\" data-start=\"2083\"\u003e\u003cp class=\"\" data-end=\"2115\" data-start=\"2085\"\u003eBarometric pressure: ±0.5%\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2138\" data-start=\"2116\"\u003e\u003cp class=\"\" data-end=\"2138\" data-start=\"2118\"\u003eTemperature: ±0.5 °C\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp class=\"\" data-end=\"2170\" data-start=\"2145\"\u003e\u003cstrong data-end=\"2168\" data-start=\"2145\"\u003eTechnical specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-end=\"2420\" data-start=\"2171\"\u003e\u003cli class=\"\" data-end=\"2203\" data-start=\"2171\"\u003e\u003cp class=\"\" data-end=\"2203\" data-start=\"2173\"\u003eDimensions: 185 × 85 × 45 mm\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2219\" data-start=\"2204\"\u003e\u003cp class=\"\" data-end=\"2219\" data-start=\"2206\"\u003eWeight: 400 g\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2248\" data-start=\"2220\"\u003e\u003cp class=\"\" data-end=\"2248\" data-start=\"2222\"\u003eOperating humidity: \u003c 95%\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2290\" data-start=\"2249\"\u003e\u003cp class=\"\" data-end=\"2290\" data-start=\"2251\"\u003eOperating temperature: 0.0 – +45.0 °C\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2328\" data-start=\"2291\"\u003e\u003cp class=\"\" data-end=\"2328\" data-start=\"2293\"\u003ePower supply: 3 AA 1.5V batteries\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2354\" data-start=\"2329\"\u003e\u003cp class=\"\" data-end=\"2354\" data-start=\"2331\"\u003eDate and time: integrated\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2394\" data-start=\"2355\"\u003e\u003cp class=\"\" data-end=\"2394\" data-start=\"2357\"\u003eCalibration report: available\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2420\" data-start=\"2395\"\u003e\u003cp class=\"\" data-end=\"2420\" data-start=\"2397\"\u003eZero Point: available\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp class=\"\" data-end=\"2451\" data-start=\"2427\"\u003e\u003cstrong data-end=\"2449\" data-start=\"2427\"\u003eStandard supply\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-end=\"2684\" data-start=\"2452\"\u003e\u003cli class=\"\" data-end=\"2478\" data-start=\"2452\"\u003e\u003cp class=\"\" data-end=\"2478\" data-start=\"2454\"\u003eXS Oxy 7 Vio oximeter\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2543\" data-start=\"2479\"\u003e\u003cp class=\"\" data-end=\"2543\" data-start=\"2481\"\u003eOXY DO7\/3MT oxygen polarographic sensor (3-meter cable)\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2570\" data-start=\"2544\"\u003e\u003cp class=\"\" data-end=\"2570\" data-start=\"2546\"\u003e1 replacement membrane\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2607\" data-start=\"2571\"\u003e\u003cp class=\"\" data-end=\"2607\" data-start=\"2573\"\u003eFilling solution (30 ml)\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2634\" data-start=\"2608\"\u003e\u003cp class=\"\" data-end=\"2634\" data-start=\"2610\"\u003eZero oxygen standard\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2659\" data-start=\"2635\"\u003e\u003cp class=\"\" data-end=\"2659\" data-start=\"2637\"\u003eInstructions for use\u003c\/p\u003e\u003c\/li\u003e\u003cli class=\"\" data-end=\"2684\" data-start=\"2660\"\u003e\u003cp class=\"\" data-end=\"2684\" data-start=\"2662\"\u003eCarrying case\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e \u003c\/p\u003e","brand":"GIORGIO BORMAC","offers":[{"title":"Default Title","offer_id":57603232498046,"sku":"GB50110202","price":695.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0959\/4873\/4846\/files\/GB50110202_--_000_45039.jpg?v=1783425419","url":"https:\/\/www.securlab.it\/en\/products\/portable-oximeter-3-m-polarographic-sensor-xs-oxy-7-vio","provider":"Securlab","version":"1.0","type":"link"}