{"product_id":"stufa-tcf-120-new-a-ventilazione-forzata","title":"TCF 120 NEW forced-air oven","description":"\u003cp\u003e\u003c\/p\u003e\u003ch3 data-end=\"50\" data-start=\"0\"\u003e\u003cstrong data-end=\"48\" data-start=\"4\"\u003eTCF 120 NEW Forced Ventilation Oven\u003c\/strong\u003e\u003c\/h3\u003e\u003ch4 data-end=\"74\" data-start=\"52\"\u003e\u003cstrong data-end=\"72\" data-start=\"57\"\u003eDescription\u003c\/strong\u003e\u003c\/h4\u003e\u003cp data-end=\"549\" data-start=\"75\"\u003eThe \u003cstrong data-end=\"122\" data-start=\"84\"\u003eTCF 120 NEW forced ventilation oven\u003c\/strong\u003e by ArgoLab is designed to ensure precise and uniform temperature control, making it ideal for laboratory applications. Thanks to the adjustable forced ventilation on three levels, it ensures optimal heat distribution and reduced heating times. The advanced programming system, intuitive display and USB data logging make it a reliable and efficient solution.\u003c\/p\u003e\u003ch4 data-end=\"588\" data-start=\"551\"\u003e\u003cstrong data-end=\"586\" data-start=\"556\"\u003eMain features\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"1036\" data-start=\"589\"\u003e\u003cli data-end=\"631\" data-start=\"589\"\u003e\u003cstrong data-end=\"611\" data-start=\"591\"\u003eWorking range:\u003c\/strong\u003e +10°C Ta … +300°C\u003c\/li\u003e\u003cli data-end=\"712\" data-start=\"632\"\u003e\u003cstrong data-end=\"665\" data-start=\"634\"\u003eBacklit LED display\u003c\/strong\u003e for clear viewing of parameters\u003c\/li\u003e\u003cli data-end=\"771\" data-start=\"713\"\u003e\u003cstrong data-end=\"747\" data-start=\"715\"\u003eData export and logging\u003c\/strong\u003e via USB flash drive\u003c\/li\u003e\u003cli data-end=\"935\" data-start=\"772\"\u003e\u003cstrong data-end=\"802\" data-start=\"774\"\u003eAdvanced programming:\u003c\/strong\u003e\u003cul data-end=\"935\" data-start=\"807\"\u003e\u003cli data-end=\"856\" data-start=\"807\"\u003e8 programmable programs with 8 steps each\u003c\/li\u003e\u003cli data-end=\"893\" data-start=\"859\"\u003eBasic single-step program\u003c\/li\u003e\u003cli data-end=\"935\" data-start=\"896\"\u003eMulti-step program up to 64 steps\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"1036\" data-start=\"936\"\u003e\u003cstrong data-end=\"965\" data-start=\"938\"\u003eAdjustable ventilation\u003c\/strong\u003e on three levels:\u003cul data-end=\"1036\" data-start=\"986\"\u003e\u003cli data-end=\"1001\" data-start=\"986\"\u003eHigh = 100%\u003c\/li\u003e\u003cli data-end=\"1020\" data-start=\"1004\"\u003eMedium = 75%\u003c\/li\u003e\u003cli data-end=\"1036\" data-start=\"1023\"\u003eLow = 50%\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"1066\" data-start=\"1038\"\u003e\u003cstrong data-end=\"1064\" data-start=\"1043\"\u003eAdvanced functions\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"1728\" data-start=\"1067\"\u003e\u003cli data-end=\"1139\" data-start=\"1067\"\u003e\u003cstrong data-end=\"1099\" data-start=\"1069\"\u003eSimultaneous display\u003c\/strong\u003e of all operating parameters\u003c\/li\u003e\u003cli data-end=\"1199\" data-start=\"1140\"\u003e\u003cstrong data-end=\"1171\" data-start=\"1142\"\u003eVisual and acoustic alarms\u003c\/strong\u003e that can be silenced by the operator\u003c\/li\u003e\u003cli data-end=\"1299\" data-start=\"1200\"\u003e\u003cstrong data-end=\"1221\" data-start=\"1202\"\u003eDigital timer:\u003c\/strong\u003e from 1 minute to 99 hours and 59 minutes, with continuous operation option\u003c\/li\u003e\u003cli data-end=\"1377\" data-start=\"1300\"\u003e\u003cstrong data-end=\"1324\" data-start=\"1302\"\u003eDelayed start\u003c\/strong\u003e to schedule the start of the heating cycle\u003c\/li\u003e\u003cli data-end=\"1444\" data-start=\"1378\"\u003e\u003cstrong data-end=\"1411\" data-start=\"1380\"\u003eSafe temperature function\u003c\/strong\u003e for sample protection\u003c\/li\u003e\u003cli data-end=\"1536\" data-start=\"1445\"\u003e\u003cstrong data-end=\"1480\" data-start=\"1447\"\u003eWork data logging:\u003c\/strong\u003e up to 2167 values, with USB download option\u003c\/li\u003e\u003cli data-end=\"1625\" data-start=\"1537\"\u003e\u003cstrong data-end=\"1565\" data-start=\"1539\"\u003eEnergy efficiency:\u003c\/strong\u003e reduced heating times and low energy consumption\u003c\/li\u003e\u003cli data-end=\"1728\" data-start=\"1626\"\u003e\u003cstrong data-end=\"1668\" data-start=\"1628\"\u003eSafety class 3.1 (DIN 12880):\u003c\/strong\u003e fluid-expansion maximum temperature controller\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"1759\" data-start=\"1730\"\u003e\u003cstrong data-end=\"1757\" data-start=\"1735\"\u003eStructure and Design\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2054\" data-start=\"1760\"\u003e\u003cli data-end=\"1830\" data-start=\"1760\"\u003e\u003cstrong data-end=\"1790\" data-start=\"1762\"\u003eØ 5 mm pass-through hole\u003c\/strong\u003e for inserting an external sensor\u003c\/li\u003e\u003cli data-end=\"1911\" data-start=\"1831\"\u003e\u003cstrong data-end=\"1859\" data-start=\"1833\"\u003eStainless steel chamber\u003c\/strong\u003e with rounded corners for easier cleaning\u003c\/li\u003e\u003cli data-end=\"1980\" data-start=\"1912\"\u003e\u003cstrong data-end=\"1953\" data-start=\"1914\"\u003eAnti-tip supports and shelves\u003c\/strong\u003e completely removable\u003c\/li\u003e\u003cli data-end=\"2054\" data-start=\"1981\"\u003e\u003cstrong data-end=\"2005\" data-start=\"1983\"\u003eDoor switch\u003c\/strong\u003e to facilitate loading and unloading of samples\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2079\" data-start=\"2056\"\u003e\u003cstrong data-end=\"2077\" data-start=\"2061\"\u003eTechnical data\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2380\" data-start=\"2080\"\u003e\u003cli data-end=\"2107\" data-start=\"2080\"\u003e\u003cstrong data-end=\"2095\" data-start=\"2082\"\u003eCapacity:\u003c\/strong\u003e 120 liters\u003c\/li\u003e\u003cli data-end=\"2149\" data-start=\"2108\"\u003e\u003cstrong data-end=\"2141\" data-start=\"2110\"\u003eMaximum shelf load:\u003c\/strong\u003e 20 kg\u003c\/li\u003e\u003cli data-end=\"2208\" data-start=\"2150\"\u003e\u003cstrong data-end=\"2187\" data-start=\"2152\"\u003eExternal dimensions (W x D x H):\u003c\/strong\u003e 810 x 760 x 750 mm\u003c\/li\u003e\u003cli data-end=\"2267\" data-start=\"2209\"\u003e\u003cstrong data-end=\"2246\" data-start=\"2211\"\u003eInternal dimensions (W x D x H):\u003c\/strong\u003e 520 x 435 x 530 mm\u003c\/li\u003e\u003cli data-end=\"2287\" data-start=\"2268\"\u003e\u003cstrong data-end=\"2279\" data-start=\"2270\"\u003eWeight:\u003c\/strong\u003e 74 kg\u003c\/li\u003e\u003cli data-end=\"2321\" data-start=\"2288\"\u003e\u003cstrong data-end=\"2312\" data-start=\"2290\"\u003ePower consumption:\u003c\/strong\u003e 1900 W\u003c\/li\u003e\u003cli data-end=\"2351\" data-start=\"2322\"\u003e\u003cstrong data-end=\"2338\" data-start=\"2324\"\u003eFrequency:\u003c\/strong\u003e 50 - 60 Hz\u003c\/li\u003e\u003cli data-end=\"2380\" data-start=\"2352\"\u003e\u003cstrong data-end=\"2372\" data-start=\"2354\"\u003ePower supply:\u003c\/strong\u003e 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2416\" data-start=\"2382\"\u003e\u003cstrong data-end=\"2414\" data-start=\"2387\"\u003ePerformance and Safety\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2645\" data-start=\"2417\"\u003e\u003cli data-end=\"2466\" data-start=\"2417\"\u003e\u003cstrong data-end=\"2454\" data-start=\"2419\"\u003eHeating time at 150°C:\u003c\/strong\u003e 24 minutes\u003c\/li\u003e\u003cli data-end=\"2514\" data-start=\"2467\"\u003e\u003cstrong data-end=\"2504\" data-start=\"2469\"\u003eTemperature variation at 150°C:\u003c\/strong\u003e ± 0,3°C\u003c\/li\u003e\u003cli data-end=\"2566\" data-start=\"2515\"\u003e\u003cstrong data-end=\"2558\" data-start=\"2517\"\u003eTemperature uniformity at 150°C:\u003c\/strong\u003e ± 3°C\u003c\/li\u003e\u003cli data-end=\"2645\" data-start=\"2567\"\u003e\u003cstrong data-end=\"2611\" data-start=\"2569\"\u003eOvertemperature safety system:\u003c\/strong\u003e electronic and electromechanical\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2676\" data-start=\"2647\"\u003e\u003cstrong data-end=\"2674\" data-start=\"2652\"\u003eStandard equipment\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2947\" data-start=\"2677\"\u003e\u003cli data-end=\"2796\" data-start=\"2677\"\u003e\u003cstrong data-end=\"2712\" data-start=\"2679\"\u003eGrated steel shelves:\u003c\/strong\u003e\u003cul data-end=\"2796\" data-start=\"2717\"\u003e\u003cli data-end=\"2758\" data-start=\"2717\"\u003e2 shelves for models up to 50 liters\u003c\/li\u003e\u003cli data-end=\"2796\" data-start=\"2761\"\u003e3 shelves for larger models\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"2876\" data-start=\"2797\"\u003e\u003cstrong data-end=\"2831\" data-start=\"2799\"\u003eCalibration report at 150°C\u003c\/strong\u003e with traceable reference instrument Accredia\u003c\/li\u003e\u003cli data-end=\"2947\" data-start=\"2877\"\u003e\u003cstrong data-end=\"2896\" data-start=\"2879\"\u003eUSB flash drive\u003c\/strong\u003e for data logging and transfer\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2984\" data-start=\"2949\"\u003e\u003cstrong data-end=\"2982\" data-start=\"2954\"\u003eReference standards\u003c\/strong\u003e\u003c\/h4\u003e\u003cp data-end=\"3106\" data-start=\"2985\"\u003eComplies with directives \u003cstrong data-end=\"3023\" data-start=\"3009\"\u003e2006\/95\/EC\u003c\/strong\u003e, \u003cstrong data-end=\"3040\" data-start=\"3025\"\u003e2004\/108\/EC\u003c\/strong\u003e, \u003cstrong data-end=\"3060\" data-start=\"3042\"\u003eEN61326-1:2006\u003c\/strong\u003e, \u003cstrong data-end=\"3080\" data-start=\"3062\"\u003eEN61010-1:2010\u003c\/strong\u003e, \u003cstrong data-end=\"3104\" data-start=\"3082\"\u003eEN61010-2-010:2003\u003c\/strong\u003e\u003c\/p\u003e\u003cp data-end=\"3275\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"3108\"\u003eThe \u003cstrong data-end=\"3132\" data-start=\"3111\"\u003eTCF 120 NEW Oven\u003c\/strong\u003e represents an advanced solution for laboratory temperature control, ensuring reliability, safety and maximum efficiency.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"GIORGIO BORMAC","offers":[{"title":"Default Title","offer_id":57603043590526,"sku":"GB41100212","price":2181.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0959\/4873\/4846\/files\/GB41100212_--_000_35933.jpg?v=1783429857","url":"https:\/\/www.securlab.it\/en\/products\/tcf-120-new-forced-air-oven","provider":"Securlab","version":"1.0","type":"link"}