{"product_id":"stufa-tcf-50-super-new-a-ventilazione-forzata","title":"TCF 50 SUPER NEW forced-air oven","description":"\u003cp\u003e\u003c\/p\u003e\u003ch3 data-end=\"55\" data-start=\"0\"\u003e\u003cstrong data-end=\"53\" data-start=\"4\"\u003eTCF 50 SUPER NEW Forced Ventilation Oven\u003cstrong data-end=\"53\" data-start=\"4\"\u003e\u003cstrong data-end=\"68\" data-start=\"57\"\u003e\u003c\/strong\u003e\u003c\/strong\u003e \u003c\/strong\u003e\u003c\/h3\u003e\u003ch4 data-end=\"105\" data-start=\"83\"\u003e\u003cstrong data-end=\"103\" data-start=\"88\"\u003eDescription\u003c\/strong\u003e\u003c\/h4\u003e\u003cp data-end=\"647\" data-start=\"106\"\u003eThe \u003cstrong data-end=\"158\" data-start=\"109\"\u003eTCF 50 SUPER NEW forced ventilation oven\u003c\/strong\u003e by ArgoLab is an advanced unit for temperature control in laboratories, equipped with a \u003cstrong data-end=\"296\" data-start=\"251\"\u003e4-inch color touchscreen display\u003c\/strong\u003e, multi-user management and specialized functions such as \u003cstrong data-end=\"377\" data-start=\"353\"\u003etemperature ramps\u003c\/strong\u003e and \u003cstrong data-end=\"443\" data-start=\"383\"\u003egraphical display of temperature trends\u003c\/strong\u003e. Thanks to its advanced technology, extensive data logging and the ability to export information via USB, it is the ideal solution for those seeking maximum precision and reliability.\u003c\/p\u003e\u003ch4 data-end=\"686\" data-start=\"649\"\u003e\u003cstrong data-end=\"684\" data-start=\"654\"\u003eMain features\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"1451\" data-start=\"687\"\u003e\u003cli data-end=\"729\" data-start=\"687\"\u003e\u003cstrong data-end=\"709\" data-start=\"689\"\u003eOperating range:\u003c\/strong\u003e +10°C Ta … +300°C\u003c\/li\u003e\u003cli data-end=\"808\" data-start=\"730\"\u003e\u003cstrong data-end=\"777\" data-start=\"732\"\u003e4-inch color touchscreen display\u003c\/strong\u003e for an intuitive interface\u003c\/li\u003e\u003cli data-end=\"972\" data-start=\"809\"\u003e\u003cstrong data-end=\"839\" data-start=\"811\"\u003eAdvanced programming:\u003c\/strong\u003e\u003cul data-end=\"972\" data-start=\"844\"\u003e\u003cli data-end=\"893\" data-start=\"844\"\u003e8 programmable programs with 8 steps each\u003c\/li\u003e\u003cli data-end=\"930\" data-start=\"896\"\u003eSingle-step basic program\u003c\/li\u003e\u003cli data-end=\"972\" data-start=\"933\"\u003eMulti-step program up to 64 steps\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"1073\" data-start=\"973\"\u003e\u003cstrong data-end=\"1002\" data-start=\"975\"\u003eAdjustable ventilation\u003c\/strong\u003e at three levels:\u003cul data-end=\"1073\" data-start=\"1023\"\u003e\u003cli data-end=\"1038\" data-start=\"1023\"\u003eHigh = 100%\u003c\/li\u003e\u003cli data-end=\"1057\" data-start=\"1041\"\u003eMedium = 75%\u003c\/li\u003e\u003cli data-end=\"1073\" data-start=\"1060\"\u003eLow = 50%\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"1229\" data-start=\"1074\"\u003e\u003cstrong data-end=\"1109\" data-start=\"1076\"\u003eData logging and alarms:\u003c\/strong\u003e\u003cul data-end=\"1229\" data-start=\"1114\"\u003e\u003cli data-end=\"1153\" data-start=\"1114\"\u003eUp to 200,000 values storable\u003c\/li\u003e\u003cli data-end=\"1194\" data-start=\"1156\"\u003eData download via USB flash drive\u003c\/li\u003e\u003cli data-end=\"1229\" data-start=\"1197\"\u003eAlarm and operation history\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"1451\" data-start=\"1230\"\u003e\u003cstrong data-end=\"1254\" data-start=\"1232\"\u003eAdvanced functions:\u003c\/strong\u003e\u003cul data-end=\"1451\" data-start=\"1259\"\u003e\u003cli data-end=\"1319\" data-start=\"1259\"\u003e\u003cstrong data-end=\"1285\" data-start=\"1261\"\u003eTemperature ramps\u003c\/strong\u003e for specialized applications\u003c\/li\u003e\u003cli data-end=\"1386\" data-start=\"1322\"\u003e\u003cstrong data-end=\"1351\" data-start=\"1324\"\u003eGraphical display\u003c\/strong\u003e of temperature trends\u003c\/li\u003e\u003cli data-end=\"1451\" data-start=\"1389\"\u003e\u003cstrong data-end=\"1415\" data-start=\"1391\"\u003eMulti-user management\u003c\/strong\u003e with three authorization levels\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"1499\" data-start=\"1453\"\u003e\u003cstrong data-end=\"1497\" data-start=\"1458\"\u003eSafety and performance functions\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"1966\" data-start=\"1500\"\u003e\u003cli data-end=\"1572\" data-start=\"1500\"\u003e\u003cstrong data-end=\"1532\" data-start=\"1502\"\u003eSimultaneous display\u003c\/strong\u003e of all operating parameters\u003c\/li\u003e\u003cli data-end=\"1632\" data-start=\"1573\"\u003e\u003cstrong data-end=\"1604\" data-start=\"1575\"\u003eVisual and acoustic alarms\u003c\/strong\u003e that can be silenced by the operator\u003c\/li\u003e\u003cli data-end=\"1717\" data-start=\"1633\"\u003e\u003cstrong data-end=\"1654\" data-start=\"1635\"\u003eDigital timer:\u003c\/strong\u003e from 1 minute to 99 hours and 59 minutes, with continuous operation\u003c\/li\u003e\u003cli data-end=\"1796\" data-start=\"1718\"\u003e\u003cstrong data-end=\"1742\" data-start=\"1720\"\u003eDelayed start\u003c\/strong\u003e to program the start of the heating cycle\u003c\/li\u003e\u003cli data-end=\"1863\" data-start=\"1797\"\u003e\u003cstrong data-end=\"1830\" data-start=\"1799\"\u003eSafe temperature function\u003c\/strong\u003e for sample protection\u003c\/li\u003e\u003cli data-end=\"1966\" data-start=\"1864\"\u003e\u003cstrong data-end=\"1906\" data-start=\"1866\"\u003eSafety class 3.1 (DIN 12880):\u003c\/strong\u003e fluid-expansion maximum temperature controller\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"1997\" data-start=\"1968\"\u003e\u003cstrong data-end=\"1995\" data-start=\"1973\"\u003eStructure and Design\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2292\" data-start=\"1998\"\u003e\u003cli data-end=\"2068\" data-start=\"1998\"\u003e\u003cstrong data-end=\"2028\" data-start=\"2000\"\u003eØ 5 mm pass-through hole\u003c\/strong\u003e for inserting an external sensor\u003c\/li\u003e\u003cli data-end=\"2149\" data-start=\"2069\"\u003e\u003cstrong data-end=\"2097\" data-start=\"2071\"\u003eStainless steel chamber\u003c\/strong\u003e with rounded corners for easier cleaning\u003c\/li\u003e\u003cli data-end=\"2218\" data-start=\"2150\"\u003e\u003cstrong data-end=\"2191\" data-start=\"2152\"\u003eAnti-tip supports and shelves\u003c\/strong\u003e completely removable\u003c\/li\u003e\u003cli data-end=\"2292\" data-start=\"2219\"\u003e\u003cstrong data-end=\"2243\" data-start=\"2221\"\u003eDoor switch\u003c\/strong\u003e to facilitate loading and unloading of samples\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2317\" data-start=\"2294\"\u003e\u003cstrong data-end=\"2315\" data-start=\"2299\"\u003eTechnical data\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2616\" data-start=\"2318\"\u003e\u003cli data-end=\"2344\" data-start=\"2318\"\u003e\u003cstrong data-end=\"2333\" data-start=\"2320\"\u003eCapacity:\u003c\/strong\u003e 50 liters\u003c\/li\u003e\u003cli data-end=\"2386\" data-start=\"2345\"\u003e\u003cstrong data-end=\"2378\" data-start=\"2347\"\u003eMaximum shelf load:\u003c\/strong\u003e 15 kg\u003c\/li\u003e\u003cli data-end=\"2445\" data-start=\"2387\"\u003e\u003cstrong data-end=\"2424\" data-start=\"2389\"\u003eExternal dimensions (W x D x H):\u003c\/strong\u003e 690 x 640 x 635 mm\u003c\/li\u003e\u003cli data-end=\"2504\" data-start=\"2446\"\u003e\u003cstrong data-end=\"2483\" data-start=\"2448\"\u003eInternal dimensions (W x D x H):\u003c\/strong\u003e 400 x 310 x 410 mm\u003c\/li\u003e\u003cli data-end=\"2524\" data-start=\"2505\"\u003e\u003cstrong data-end=\"2516\" data-start=\"2507\"\u003eWeight:\u003c\/strong\u003e 54 kg\u003c\/li\u003e\u003cli data-end=\"2557\" data-start=\"2525\"\u003e\u003cstrong data-end=\"2549\" data-start=\"2527\"\u003ePower consumption:\u003c\/strong\u003e 980 W\u003c\/li\u003e\u003cli data-end=\"2587\" data-start=\"2558\"\u003e\u003cstrong data-end=\"2574\" data-start=\"2560\"\u003eFrequency:\u003c\/strong\u003e 50 - 60 Hz\u003c\/li\u003e\u003cli data-end=\"2616\" data-start=\"2588\"\u003e\u003cstrong data-end=\"2608\" data-start=\"2590\"\u003ePower supply:\u003c\/strong\u003e 230 V\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2652\" data-start=\"2618\"\u003e\u003cstrong data-end=\"2650\" data-start=\"2623\"\u003ePerformance and Safety\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"2881\" data-start=\"2653\"\u003e\u003cli data-end=\"2702\" data-start=\"2653\"\u003e\u003cstrong data-end=\"2690\" data-start=\"2655\"\u003eHeating time at 150°C:\u003c\/strong\u003e 20 minutes\u003c\/li\u003e\u003cli data-end=\"2750\" data-start=\"2703\"\u003e\u003cstrong data-end=\"2740\" data-start=\"2705\"\u003eTemperature variation at 150°C:\u003c\/strong\u003e ± 0.3°C\u003c\/li\u003e\u003cli data-end=\"2802\" data-start=\"2751\"\u003e\u003cstrong data-end=\"2794\" data-start=\"2753\"\u003eTemperature uniformity at 150°C:\u003c\/strong\u003e ± 3°C\u003c\/li\u003e\u003cli data-end=\"2881\" data-start=\"2803\"\u003e\u003cstrong data-end=\"2847\" data-start=\"2805\"\u003eOvertemperature safety system:\u003c\/strong\u003e electronic and electromechanical\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"2912\" data-start=\"2883\"\u003e\u003cstrong data-end=\"2910\" data-start=\"2888\"\u003eStandard equipment\u003c\/strong\u003e\u003c\/h4\u003e\u003cul data-end=\"3183\" data-start=\"2913\"\u003e\u003cli data-end=\"3032\" data-start=\"2913\"\u003e\u003cstrong data-end=\"2948\" data-start=\"2915\"\u003eGrated steel shelves:\u003c\/strong\u003e\u003cul data-end=\"3032\" data-start=\"2953\"\u003e\u003cli data-end=\"2994\" data-start=\"2953\"\u003e2 shelves for models up to 50 liters\u003c\/li\u003e\u003cli data-end=\"3032\" data-start=\"2997\"\u003e3 shelves for larger models\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003cli data-end=\"3112\" data-start=\"3033\"\u003e\u003cstrong data-end=\"3067\" data-start=\"3035\"\u003eCalibration report at 150°C\u003c\/strong\u003e with traceable Accredia reference instrument\u003c\/li\u003e\u003cli data-end=\"3183\" data-start=\"3113\"\u003e\u003cstrong data-end=\"3132\" data-start=\"3115\"\u003eUSB flash drive\u003c\/strong\u003e for data logging and transfer\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 data-end=\"3220\" data-start=\"3185\"\u003e\u003cstrong data-end=\"3218\" data-start=\"3190\"\u003eReference standards\u003c\/strong\u003e\u003c\/h4\u003e\u003cp data-end=\"3342\" data-start=\"3221\"\u003eCompliant with directives \u003cstrong data-end=\"3259\" data-start=\"3245\"\u003e2006\/95\/EC\u003c\/strong\u003e, \u003cstrong data-end=\"3276\" data-start=\"3261\"\u003e2004\/108\/EC\u003c\/strong\u003e, \u003cstrong data-end=\"3296\" data-start=\"3278\"\u003eEN61326-1:2006\u003c\/strong\u003e, \u003cstrong data-end=\"3316\" data-start=\"3298\"\u003eEN61010-1:2010\u003c\/strong\u003e, \u003cstrong data-end=\"3340\" data-start=\"3318\"\u003eEN61010-2-010:2003\u003c\/strong\u003e\u003c\/p\u003e\u003cp data-end=\"3561\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"3344\"\u003eThe \u003cstrong data-end=\"3373\" data-start=\"3347\"\u003eTCF 50 SUPER NEW Oven\u003c\/strong\u003e is the perfect choice for those who need a precision unit with advanced temperature control features, ensuring reliability, safety and energy efficiency.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"GIORGIO BORMAC","offers":[{"title":"Default Title","offer_id":57603045720446,"sku":"GB41100602","price":2122.88,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0959\/4873\/4846\/files\/GB41100602_--_000_37244.jpg?v=1783429860","url":"https:\/\/www.securlab.it\/en\/products\/tcf-50-super-new-forced-air-oven","provider":"Securlab","version":"1.0","type":"link"}