{"product_id":"analizzatore-poc-di-coagulazione-qlabs","title":"Analizzatore POC di coagulazione qLabs®","description":"\u003ch3 data-end=\"225\" data-start=\"156\"\u003e\n\u003cstrong data-end=\"225\" data-start=\"160\"\u003eqLabs® ElectroMeter – Sistema per il Monitoraggio di PT e INR\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"582\" data-start=\"227\"\u003e\n\u003cstrong data-end=\"251\" data-start=\"227\"\u003eDescrizione Generale\u003c\/strong\u003e\u003cbr data-end=\"254\" data-start=\"251\"\u003e\nIl sistema \u003cstrong data-end=\"282\" data-start=\"265\"\u003eqLabs® PT-INR\u003c\/strong\u003e è progettato per la \u003cstrong data-end=\"361\" data-start=\"303\"\u003emisurazione quantitativa del tempo di protrombina (PT)\u003c\/strong\u003e e del \u003cstrong data-end=\"414\" data-start=\"368\"\u003erapporto internazionale normalizzato (INR)\u003c\/strong\u003e su \u003cstrong data-end=\"454\" data-start=\"418\"\u003ecampioni di sangue intero fresco\u003c\/strong\u003e, capillare o venoso.\u003cbr data-end=\"478\" data-start=\"475\"\u003e\nÈ destinato \u003cstrong data-end=\"537\" data-start=\"490\"\u003eesclusivamente all’uso diagnostico in vitro\u003c\/strong\u003e e \u003cstrong data-end=\"581\" data-start=\"540\"\u003enon è indicato per scopi di screening\u003c\/strong\u003e.\n\u003c\/p\u003e\n\u003ch3 data-end=\"625\" data-start=\"589\"\u003e\n\u003cstrong data-end=\"623\" data-start=\"593\"\u003ePrincipio di Funzionamento\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"651\" data-start=\"626\"\u003eIl sistema si compone di:\u003c\/p\u003e\n\u003cul data-end=\"729\" data-start=\"652\"\u003e\n\u003cli data-end=\"692\" data-start=\"652\"\u003e\n\u003cp data-end=\"692\" data-start=\"654\"\u003e\n\u003cstrong data-end=\"677\" data-start=\"654\"\u003eqLabs® ElectroMeter\u003c\/strong\u003e (elettrometro)\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"729\" data-start=\"693\"\u003e\n\u003cp data-end=\"729\" data-start=\"695\"\u003e\n\u003cstrong data-end=\"729\" data-start=\"695\"\u003eStrisce reattive qLabs® PT-INR\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"920\" data-start=\"731\"\u003e\nIl dispositivo riconosce automaticamente l’inserimento della striscia, la porta alla \u003cstrong data-end=\"853\" data-start=\"816\"\u003etemperatura operativa predefinita\u003c\/strong\u003e e ne monitora il comportamento durante la coagulazione del sangue.\n\u003c\/p\u003e\n\u003cp data-end=\"1348\" data-start=\"922\"\u003e\nDopo l’applicazione di una \u003cstrong data-end=\"969\" data-start=\"949\"\u003egoccia di sangue\u003c\/strong\u003e, il campione viene convogliato in due aree: \u003cstrong data-end=\"1022\" data-start=\"1014\"\u003etest\u003c\/strong\u003e e \u003cstrong data-end=\"1038\" data-start=\"1025\"\u003econtrollo\u003c\/strong\u003e, dove reagisce con i \u003cstrong data-end=\"1084\" data-start=\"1060\"\u003ereagenti prestampati\u003c\/strong\u003e.\u003cbr data-end=\"1088\" data-start=\"1085\"\u003e\nAll’interno di ogni area si trovano \u003cstrong data-end=\"1147\" data-start=\"1124\"\u003ecoppie di elettrodi\u003c\/strong\u003e che rilevano variazioni di corrente causate dal processo di coagulazione.\u003cbr data-end=\"1224\" data-start=\"1221\"\u003e\nL’elettrometro analizza tali variazioni per determinare con precisione il \u003cstrong data-end=\"1327\" data-start=\"1298\"\u003etempo di protrombina (PT)\u003c\/strong\u003e e il \u003cstrong data-end=\"1347\" data-start=\"1333\"\u003evalore INR\u003c\/strong\u003e.\n\u003c\/p\u003e\n\u003ch3 data-end=\"1385\" data-start=\"1355\"\u003e\n\u003cstrong data-end=\"1385\" data-start=\"1359\"\u003eManutenzione e Pulizia\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"1413\" data-start=\"1387\"\u003e\n\u003cstrong data-end=\"1412\" data-start=\"1387\"\u003eFrequenza consigliata\u003c\/strong\u003e:\n\u003c\/p\u003e\n\u003cul data-end=\"1636\" data-start=\"1414\"\u003e\n\u003cli data-end=\"1500\" data-start=\"1414\"\u003e\n\u003cp data-end=\"1500\" data-start=\"1416\"\u003e\nDopo ogni utilizzo, soprattutto in presenza di sporco o materiale biologico visibile\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1546\" data-start=\"1501\"\u003e\n\u003cp data-end=\"1546\" data-start=\"1503\"\u003e\nPrima di ogni utilizzo su un nuovo paziente\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1595\" data-start=\"1547\"\u003e\n\u003cp data-end=\"1595\" data-start=\"1549\"\u003e\nDopo applicazione eccessiva di sangue (\u0026gt;20 µL)\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1636\" data-start=\"1596\"\u003e\n\u003cp data-end=\"1636\" data-start=\"1598\"\u003e\nRegolarmente, almeno una volta al mese\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1670\" data-start=\"1638\"\u003e\n\u003cstrong data-end=\"1669\" data-start=\"1638\"\u003eAree da pulire\/disinfettare\u003c\/strong\u003e:\n\u003c\/p\u003e\n\u003col data-end=\"1773\" data-start=\"1671\"\u003e\n\u003cli data-end=\"1708\" data-start=\"1671\"\u003e\n\u003cp data-end=\"1708\" data-start=\"1674\"\u003e\nPorta d’inserimento della striscia\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1719\" data-start=\"1709\"\u003e\n\u003cp data-end=\"1719\" data-start=\"1712\"\u003eDisplay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1752\" data-start=\"1720\"\u003e\n\u003cp data-end=\"1752\" data-start=\"1723\"\u003e\nScocca anteriore e posteriore\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1773\" data-start=\"1753\"\u003e\n\u003cp data-end=\"1773\" data-start=\"1756\"\u003ePulsanti frontali\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-end=\"1870\" data-start=\"1775\"\u003e\n\u003cstrong data-end=\"1783\" data-start=\"1775\"\u003eNota\u003c\/strong\u003e: attenersi sempre ai protocolli interni della struttura sanitaria per la disinfezione.\n\u003c\/p\u003e\n\u003ch3 data-end=\"1907\" data-start=\"1877\"\u003e\n\u003cstrong data-end=\"1907\" data-start=\"1881\"\u003eCondizioni di Utilizzo\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"2036\" data-start=\"1908\"\u003e\n\u003cli data-end=\"1950\" data-start=\"1908\"\u003e\n\u003cp data-end=\"1950\" data-start=\"1910\"\u003e\n\u003cstrong data-end=\"1935\" data-start=\"1910\"\u003eTemperatura operativa\u003c\/strong\u003e: 10°C – 35°C\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2003\" data-start=\"1951\"\u003e\n\u003cp data-end=\"2003\" data-start=\"1953\"\u003e\n\u003cstrong data-end=\"1973\" data-start=\"1953\"\u003eUmidità relativa\u003c\/strong\u003e: 10% – 90% (senza condensa)\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2036\" data-start=\"2004\"\u003e\n\u003cp data-end=\"2036\" data-start=\"2006\"\u003e\n\u003cstrong data-end=\"2028\" data-start=\"2006\"\u003eAltitudine massima\u003c\/strong\u003e: 4300 m\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2070\" data-start=\"2043\"\u003e\n\u003cstrong data-end=\"2070\" data-start=\"2047\"\u003eSpecifiche Tecniche\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"2339\" data-start=\"2071\"\u003e\n\u003cli data-end=\"2111\" data-start=\"2071\"\u003e\n\u003cp data-end=\"2111\" data-start=\"2073\"\u003e\n\u003cstrong data-end=\"2087\" data-start=\"2073\"\u003eProcessore\u003c\/strong\u003e: ARM Cortex-M4 32 bit\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2145\" data-start=\"2112\"\u003e\n\u003cp data-end=\"2145\" data-start=\"2114\"\u003e\n\u003cstrong data-end=\"2125\" data-start=\"2114\"\u003eDisplay\u003c\/strong\u003e: LCD 320 x 480 mm\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2177\" data-start=\"2146\"\u003e\n\u003cp data-end=\"2177\" data-start=\"2148\"\u003e\n\u003cstrong data-end=\"2163\" data-start=\"2148\"\u003eTouchscreen\u003c\/strong\u003e: Capacitivo\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2282\" data-start=\"2178\"\u003e\n\u003cp data-end=\"2200\" data-start=\"2180\"\u003e\n\u003cstrong data-end=\"2197\" data-start=\"2180\"\u003eAlimentazione\u003c\/strong\u003e:\n\u003c\/p\u003e\n\u003cul data-end=\"2282\" data-start=\"2203\"\u003e\n\u003cli data-end=\"2244\" data-start=\"2203\"\u003e\n\u003cp data-end=\"2244\" data-start=\"2205\"\u003e\nEsterna: 100–240V ~ 50\/60Hz, 0.4A max\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2282\" data-start=\"2247\"\u003e\n\u003cp data-end=\"2282\" data-start=\"2249\"\u003e\nInterna: batteria al litio 3.7V\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2319\" data-start=\"2283\"\u003e\n\u003cp data-end=\"2319\" data-start=\"2285\"\u003e\n\u003cstrong data-end=\"2299\" data-start=\"2285\"\u003eDimensioni\u003c\/strong\u003e: 148 x 70 x 26 mm\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2339\" data-start=\"2320\"\u003e\n\u003cp data-end=\"2339\" data-start=\"2322\"\u003e\n\u003cstrong data-end=\"2330\" data-start=\"2322\"\u003ePeso\u003c\/strong\u003e: 199 g\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2378\" data-start=\"2346\"\u003e\n\u003cstrong data-end=\"2378\" data-start=\"2350\"\u003eClassificazione e Codici\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"2514\" data-start=\"2379\"\u003e\n\u003cli data-end=\"2401\" data-start=\"2379\"\u003e\n\u003cp data-end=\"2401\" data-start=\"2381\"\u003e\n\u003cstrong data-end=\"2388\" data-start=\"2381\"\u003eCND\u003c\/strong\u003e: W02079080\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2442\" data-start=\"2402\"\u003e\n\u003cp data-end=\"2442\" data-start=\"2404\"\u003e\n\u003cstrong data-end=\"2431\" data-start=\"2404\"\u003eRepertorio Ministeriale\u003c\/strong\u003e: 1773492\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2514\" data-start=\"2443\"\u003e\n\u003cp data-end=\"2514\" data-start=\"2445\"\u003e\n\u003cstrong data-end=\"2458\" data-start=\"2445\"\u003eClasse CE\u003c\/strong\u003e: ST – Test autodiagnostici (non inclusi in Allegato II)\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Securlab","offers":[{"title":"Default Title","offer_id":57603152642430,"sku":"0608732","price":630.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0959\/4873\/4846\/files\/0608732_--_000_51864.jpg?v=1782252148","url":"https:\/\/www.securlab.it\/products\/analizzatore-poc-di-coagulazione-qlabs","provider":"Securlab","version":"1.0","type":"link"}