Automatic syringe pump
Automatic syringe pump
Shipped in 24/48 h
Couldn't load pickup availability
Description
Description
AUTOMATIC SYRINGE PUMP
Syringe pump with lightweight construction
and compact dimensions with easy syringe installation through
"one-touch"
mode via sliding hook, the different information can be easily viewed
through the LCD display.
The settings and use of the device
are extremely simple.
The product is supplied with a battery.
Flexible
flow volume setting.
- Complete dosage program:
automatically calculates the amount required for infusion by examining
the patient's weight, the injection mass and the liquefaction.
-
Anti-vein occlusion function: when the preset value is reached,
automatic conversion to low-flow speed of 0.1ml/h occurs in order
to prevent the risk of vein occlusion due to blood coagulation.
- Compatibility
with 5 major syringe brands: it is possible to set the system by choosing from the following syringe manufacturers:
BD (Plastipak,
Precise), TERUMO, RAYS, PENTAFERTE, KOVA.
Alarm and warning function:
notifies errors and emergency situations with a LED light and acoustic signal,
simultaneous visual and sound alarm system.
Setting
of the occlusion error range: the plasma occlusion pressure level is adjustable high, medium and low
depending on the patient's age.
We are able to calibrate our pumps for other syringe brands,
please provide a minimum of 5 samples. Availability
in 60 days. Calibration
is possible with 10/20/30/50 ml syringes.
Technical
characteristics
• Flow adjustment range
• 10ml syringe: 0.1-300ml/h
• 20ml syringe: 0.1-400ml/h
• 30ml syringe: 0.1-500ml/h
• 50ml syringe: 0.1-1200ml/h
• Flow volume error margin
±3%
• Infusion volume limit range: 0.1 ~ 999.9 ml (infusion
interval 0.1ml)
• Total estimated volume range: 0.1 ~ 999.9 ml
(infusion interval 0.1ml)
• K.V.O range (vein maintenance function)
: 1 ~ ml/h adjustable
• Dimensions: (LxWxH) 220 x 130 x 108 mm
•
Weight: 2 kg
• Rapid flow volume (Purge)
• 0.1 ~ 1200
ml/h adjustable
• Bolus 0.1 ~ 1200 ml/h, 0.1 ~ 1000 ml adjustable
•
Paramedic staff call
• DC12V, 1A
• Alarm characteristics
• Occlusion, K.V.O (infusion completion), standby,
nearly empty, low battery indication, device malfunction (CPU error), lever/slider hook disengaged, syringe disengaged.
•
Special features
• Key lock, function keys, data storage, remaining
time, alarm repeat, open system, K.V.O., purge,
bolus,
anti-bolus, occlusion level, recall previous settings
• Power supply
: AC 110V / 220V, 50/60Hz and DC9.6V
• Internal power adapter DC24V
/ 1A
• Maximum power consumption 45VA
• Electric shock protection
level
• Class 1, internal power source device, CF type
• Water resistance level IPX2
• Battery type
Ni-MH
• Battery life 5 hours at (5ml/h).
• Battery charging
time Minimum 6 hours
• Battery useful life 6 months
Technical specifications
Technical specifications
| Weight | 2 kg |
| Product Type | Pompa a siringa automatica |
| Power Supply | Elettrico |
| Display | Lcd |
| Battery Type | Ni-MH |