Multiparameter monitor for measuring pulse oximetry and blood pressure RIESTER RVS-100 - 1960-RRXPE with printer
Multiparameter monitor for measuring pulse oximetry and blood pressure RIESTER RVS-100 - 1960-RRXPE with printer
Shipped in 24/48 h
Couldn't load pickup availability
Description
Description
The RIESTER RVS-100 multiparameter monitor - 1960-RRXPE with printer is an advanced instrument for measuring pulse oximetry and blood pressure, designed to meet the needs of modern healthcare systems. This device, equipped with an intuitive touchscreen, is ideal for use on patients of all ages, from newborns to adults.
Main features of the RIESTER RVS-100
- Measurement modes: Monitor, Spot-check, Triage
- 8” color TFT touchscreen: Highly responsive with intuitive user interface and integrated help function
- Parameter display: SYS, DIA, MAP, pulse, temperature, plethysmogram
- Early warning systems: EWS, NEWS and MEWS
- Clinical-grade NIBP: With averaging calculation (2-5 readings) and neonatal mode
- Bluetooth connection: Compatible with Riester ‘tymPRO’ and ‘sensioPRO’ thermometers
- Riester Oximax SpO2: Neonatal mode included
- Electronic medical record (EMR) connection: HL7 standard
- LAN connection: Included as standard
- Programmable alarms: Audible and visual with 3 priority levels
- Internal memory: Capacity for 5,000 measurements
- Lithium-ion battery: 11-hour autonomy in automatic mode
Detailed technical specifications
Blood pressure measurement (NIBP)
- Measurement method: Automatic oscillometric
- Measurement range:
- Adults: SYS 30-270 mmHg, DIA 10-220 mmHg, MAP 20-235 mmHg
- Children: SYS 30-235 mmHg, DIA 10-220 mmHg, MAP 20-225 mmHg
- Newborns: SYS 30-135 mmHg, DIA 10-110 mmHg, MAP 20-125 mmHg
- Cuff pressure range: 0-280 mmHg, resolution 1 mmHg
- Pressure accuracy: Static ±3 mmHg / Clinical ±5 mmHg, standard deviation = 8 mmHg
- Pulse rate range: 40-240 bpm, accuracy 1 bpm
- Initial inflation pressure:
- Adults: 160 mmHg
- Children: 130 mmHg
- Newborns: 75 mmHg
- Double overpressure protection: Hardware and software
- Alarm range: SYS, DIA, MAP 0 - 300 mmHg
Pulse oximetry measurement (SpO2)
- Measurement range: 0-100 %, resolution 1%
- Accuracy: ±2% (70-100%), ±3% (40-69%), unspecified (0-39%)
- Alarm range: 0-100%
- Average time: 4 sec, 8 sec, 16 sec
- Heart rate range: 20-250 bpm, resolution 1 bpm
- Accuracy: ±1% or ± 1 bpm, whichever is higher
Monitor and alarms
- Alarm: Bright LEDs (red, yellow, cyan), voice messages, audible alarm, QRS tone
- Supports high tones and multiple volume levels: Alarm tones compliant with IEC 60601-1-8 requirements
- Pressure: 45-85 dB test distance 1 meter from the tone
Ports and connectivity
- Inputs: 1 AC input, 1 standard RJ45 interface (100 BASE-TX, IEEE 802.3), 4 USB ports, 1 equipotential grounding point, 1 RJ11 connector for nurse call
- Output port: DC 15V/1.2 A
Power supply and battery
- Power supply: 100 - 240 V AC, 50/60 Hz
- Battery: Rechargeable lithium-ion, 10.8 V VC, 6,600 mAh
- Full charging time: 6 hours
- Operating time: Approximately 11 hours (new and fully charged battery, with SpO2, Temp and NIBP modules in AUTO mode (15-minute interval))
- Indicators: Low battery and charging in progress
Dimensions and weight
- Monitor dimensions: 303x110x h 230 mm (11.93x9.05x4.33 inches)
- Weight: 3600 g (7.94 lb) including temperature module and printer
Standard equipment
- Adult SpO2 sensor
- SpO2 extension cable
- NIBP extension tube
- 2 cuffs (adult and adult large with connectors)
- Manual (GB, IT. On request FR, DE, ES, RU)
Technical specifications
Technical specifications
| Weight | 3600 g |
| Product Type | Monitor multiparametro |
| Power Supply | Elettrico |
| Height | 230 mm |
| Battery Type | Agli ioni di litio |