Fiab F3001ECG Stamp Electrodes - crocodile clip - Pack of 100 pcs
Fiab F3001ECG Stamp Electrodes - crocodile clip - Pack of 100 pcs
Shipped in 5-10 business days
Couldn't load pickup availability
Description
Description
Pre-gelled Disposable Stamp Electrodes for ECG with Crocodile Clip - Pack of 100 Pieces
The FIAB F3001ECG pre-gelled disposable electrodes are designed to ensure maximum reliability during electrocardiographic (ECG) signal recordings. Compatible with any electrocardiograph on the market, these electrodes are pre-gelled with solid gel and equipped with a crocodile clip, making them ideal for a secure and stable connection.
Technical Specifications
These disposable electrodes feature a series of technical characteristics that make them an excellent choice for medical professionals:
- Description: Disposable electrode pre-gelled with solid gel for ECG
- Dimensions: 34x23mm
- Gel: Solid-state biocompatible medical adhesive gel
- Conductor Material: Ag/AgCl
- Connection: Direct with crocodile clip
- Regulatory Compliance: Directive 93/42/EEC (D.L. 46/97), Class I Device, ANSI/AAMI EC12:2000 “Disposable ECG Electrodes”
- Compatibility: Compatible with any electrocardiograph on the market
- Latex Free: The product does not contain latex
Electrical Characteristics
The FIAB F3001ECG electrodes comply with ANSI/AAMI EC12:2000 standards, ensuring excellent performance in the following specifications:
- Impedance at 10Hz for 12 electrode pairs: ANSI/AAMI Max Value: 2 kO, Test Result: 534 O
- Single pair impedance at 10Hz: ANSI/AAMI Max Value: 3 kO, Test Result: 610 O
- Offset voltage: ANSI/AAMI Max Value: 100 mV, Test Result: 0.79 mV
- Combined offset instability and intrinsic noise: ANSI/AAMI Max Value: 150 µV, Test Result: 54 µV
- Residual voltage after defibrillation (5 sec): ANSI/AAMI Max Value: 100 mV, Test Result: 19.8 mV
- Polarization voltage rate of change: ANSI/AAMI Max Value: 1 mV/sec, Test Result: 0.21 mV/sec
- Impedance at 10 Hz after test: ANSI/AAMI Max Value: 3 kO, Test Result: 197 O
- Bias current tolerance: ANSI/AAMI Max Value: 100 mV, Test Result: 19.1 mV
Packaging
The electrodes are packaged in a heat-sealed paper and aluminum bag, ensuring maximum protection and preservation of the product. Each pack contains 100 pieces, ideal for prolonged use in clinical and hospital settings.
Advantages of FIAB F3001ECG Electrodes
Choosing FIAB F3001ECG electrodes means opting for a high-quality product, compliant with international standards and designed to offer excellent performance. Among the main advantages:
- Reliability: Consistent and reliable performance during ECG recordings
- Compatibility: Usable with any electrocardiograph on the market
- Safety: Compliant with ANSI/AAMI EC12:2000 standards
- Convenience: Pack of 100 pieces for prolonged use
- Hygiene: Disposable product, reducing the risk of contamination
Trust FIAB F3001ECG electrodes to ensure maximum accuracy and safety in your electrocardiographic recordings.
Technical specifications
Technical specifications
| Safety Features | Latex free |
| Product Type | Elettrodi monouso per ECG |
| Medical Device Class | I |