GIMA K12 touchscreen multiparameter monitor - ECG, RESP, TEMP, NIBP, SpO2
GIMA K12 touchscreen multiparameter monitor - ECG, RESP, TEMP, NIBP, SpO2
Shipped in 24/48 h
Couldn't load pickup availability
Description
Description
GIMA K12 touchscreen multiparameter monitor - ECG, RESP, TEMP, NIBP, SpO2
Multifunctional monitor designed to monitor the vital physiological signs of adult, pediatric, and neonatal patients. This advanced device enables real-time recording and display of various parameters, providing a complete analysis of the patient's physiological condition.
Product Features:
- Ergonomic design with intuitive user interface
USB port for data transfer and software update
- Display of up to 9 traces on on-screen waveforms
- Compatibility with Windows environment for easy management
Visual and audible alarm for physiological and technical anomalies
- Large memory capacity
- Suitable for use with original Nellcor sensors
Protection against defibrillator discharges and resistance to electrosurgical interference
Detection and inhibition of cardiac pacemaker pulses
Standard Equipment:
- Adult SpO2 probe
- Adult NIBP cuff
- SpO2 extension cable
- 5-lead ECG cable with button connector
- Skin temperature probe
- Power cable
- Rechargeable lithium battery
- Dust cover
Manual: GB, FR, IT, ES, PL, RU
Note: The printer is not included.
Technical Specifications:
ECG
- Input dynamic range: ±(0.5~5 mVp)
- Differential input impedance: =10 MO
Bandwidth:
- 0.05~150 Hz (Diagnostic)
- 0.5~40 Hz (Monitoring)
- 1~20 Hz (Operation)
CMRR:
- =90 dB (Diagnostic)
- =105 dB (Monitoring & Operation)
- Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
Sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
HR measurement range: 15~350 bpm ±1% or ±2 bpm, whichever is greater
Pacemaker pulse detection and inhibition function
RESP
Measurement range: 0~120 rpm ±5% or ±2 rpm, whichever is greater
TEMP
- Measurement range: 21.0~50.0 °C ±0.2 °C between 25~45 °C
NIBP
- Technique: Oscillometric method
Typical measurement time: <30 seconds (adult cuff)
NIBP SYS measurement range:
- 40~275 mmHg (Adults)
- 40~200 mmHg (Pediatric)
- 40~135 mmHg (Neonates)
NIBP DIA measurement range:
- 10~210 mmHg (Adults)
- 10~150 mmHg (Pediatric)
- 10~95 mmHg (Neonates)
NIBP MAP measurement range:
- 20~230 mmHg (Adults)
- 20~165 mmHg (Pediatric)
- 20~110 mmHg (Neonates)
NIBP measurement accuracy:
- Mean difference: ±5 mmHg
- Standard deviation: 8 mmHg
- NIBP measurement modes: Manual, Auto, STAT, Multi-cycle
- Auto-measurement intervals: 1-480 min
SpO2
- Technique: Dual-wavelength optical method
Measurement range: 0%~100% ±2% for SpO2 range 70~100%
PR measurement range: 30~250 bpm ±2 bpm or ±2%, whichever is greater
- Low perfusion performance: Up to 0.3%
Other Features
- Power supply: AC 100-240 V, 50/60 Hz, 60 VA
- Built-in lithium battery: 11.1V/4400 mAh
- Screen: 12" TFT screen
- Alarm method: 3-level audible-visual alarm
- Network: Ethernet
- Safety standard: IEC 60601-1
Technical specifications
Technical specifications
| Functional Features | Ergonomico |
| Product Type | Monitor multiparametrico |
| Power Supply | Elettrico |
| Voltage | 11,1 V |
| Battery Type | Batteria ricaricabile al litio |